Interlaboratory study of a method for determining nonvolatile organic carbon in aquifer materials

被引:17
作者
Caughey, ME
Barcelona, MJ
Powell, RM
Cahill, RA
Gron, C
Lawrenz, D
Meschi, PL
机构
[1] UNIV MICHIGAN,ANN ARBOR,MI 48109
[2] MANTECH ENVIRONM RES SERV CORP,ADA,OK 74820
[3] ILLINOIS STATE GEOL SURVEY,CHAMPAIGN,IL 61820
[4] RISO NATL LAB,DK-4000 RISO,DENMARK
[5] LECO CORP,ST JOSEPH,MI 49085
[6] UIC INC,JOLIET,IL 60343
来源
ENVIRONMENTAL GEOLOGY | 1995年 / 26卷 / 04期
关键词
aquifer material; organic carbon; interlaboratory method evaluation;
D O I
10.1007/BF00770471
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The organic carbon fraction in aquifer materials exerts a major influence on the subsurface mobilities of organic and organic-associated contaminants. The spatial distribution of total organic carbon (TOC) in aquifer materials must be determined before the transport of hydrophobic organic pollutants in aquifers can be modeled accurately. Previous interlaboratory studies showed that it is difficult to measure TOC concentrations <0.1% in aquifer materials, when total inorganic carbon (TIG) concentrations are >1%. We have tested a new analytical method designed to improve the accuracy and precision of nonvolatile TOC quantitation in geologic materials that also contain carbonate minerals. Four authentic aquifer materials and one NIST standard reference material were selected as test materials for a blind collaborative study. Nonvolatile TOC in these materials ranged from 0.05 to 1.4%, while TIC ranged from 0.46 to 12.6%. Sample replicates were digested with sulfurous acid, dried at 40 degrees C, and then combusted at 950 degrees C using LECO or UIC instruments. For the three test materials that contained >2% TIC, incomplete acidification resulted in a systematic positive bias of TOC values reported by five of the six laboratories that used the test method. Participants did not have enough time to become proficient with the new method before they analyzed the test materials. A seventh laboratory successfully used an alternative method that analyzed separate liquid and solid fractions of the acidified sample residues.
引用
收藏
页码:211 / 219
页数:9
相关论文
共 19 条
[1]  
ALASAM IS, 1990, CHEM GEOL, V80, P119
[2]  
ALLMAN M, 1972, GEOLOGICAL LABORATOR
[3]  
BALL W P, 1990, Journal of Contaminant Hydrology, V5, P253, DOI 10.1016/0169-7722(90)90040-N
[4]   OXIDATION REDUCTION CAPACITIES OF AQUIFER SOLIDS [J].
BARCELONA, MJ ;
HOLM, TR .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1991, 25 (09) :1565-1572
[5]   ANALYSIS OF CARBON IN CALCAREOUS SOILS USING A 2 TEMPERATURE DRY COMBUSTION INFRARED INSTRUMENTAL PROCEDURE [J].
CHICHESTER, FW ;
CHAISON, RF .
SOIL SCIENCE, 1992, 153 (03) :237-241
[6]  
FROELICH PN, 1980, LIMNOL OCEANOGR, V25, P564
[7]  
GIBBS RJ, 1977, J SEDIMENT PETROL, V47, P547
[8]  
GU B, 1994, ENVIRON SCI TECHNOL, V8, P138
[9]  
HORWITZ W, 1989, J ASSOC OFF ANA CHEM, V72, P145
[10]   DETERMINATION OF THE FORMS OF CARBON IN GEOLOGIC MATERIALS [J].
JACKSON, LL ;
ROOF, SR .
GEOSTANDARDS NEWSLETTER, 1992, 16 (02) :317-323