LOCATION OF THE PHENOMENA OF PREMATURE CAPACITY LOSS DURING CYCLING OF LEAD-ACID-BATTERIES WITH LEAD GRIDS

被引:25
作者
DIMITROV, MK
PAVLOV, D
机构
[1] Central Laboratory of Electrochemical Power Sources, Bulgarian Academy of Sciences, Sofia
关键词
D O I
10.1016/0378-7753(93)90018-V
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Investigations of lead/acid cells with specially designed positive plates containing pure-lead and lead-antimony subgrids under various cycling modes have been performed. It has been established that the phenomena causing premature capacity loss proceed both in the corrosion layer and at its interfaces with the grid metal and the active material. Additions of antimony to the positive active mass do not improve substantially the life of cells prepared with positive plates based on pure-lead grids.
引用
收藏
页码:203 / 210
页数:8
相关论文
共 11 条
[1]  
BORGER W, 1989, POWER SOURCES, V12, P131
[2]  
BURBANK J, 1970, J ELECTROCHEM SOC, V117, P299
[3]  
CAULDER SM, 1974, J ELECTROCHEM SOC, V121, P1546, DOI 10.1149/1.2401730
[4]  
CHANG TG, 1984, P S ADV LEAD ACID BA, V8414
[5]  
FUCHIDA K, 1982, ILZRO LE276 PROJ FIN
[6]   PREMATURE CAPACITY-LOSS MECHANISMS IN LEAD-ACID-BATTERIES [J].
HOLLENKAMP, AF ;
CONSTANTI, KK ;
HUEY, AM ;
KOOP, MJ ;
APUTEANU, L .
JOURNAL OF POWER SOURCES, 1992, 40 (1-2) :125-136
[7]  
MONAHOV B, 1993, JUN P INT C LEAD AC, P61
[8]   SUPPRESSION OF PREMATURE CAPACITY LOSS BY METHODS BASED ON THE GEL-CRYSTAL CONCEPT OF THE PBO2 ELECTRODE [J].
PAVLOV, D .
JOURNAL OF POWER SOURCES, 1993, 46 (2-3) :171-190
[9]  
RAND DAJ, 1988, J POWER SOURCES, V23, P257
[10]  
SCHUMACHER EE, 1935, T ELECTROCHEMICAL SO, V68, P309