RADIATION EXPOSURE TO ANGIOGRAPHERS UNDER DIFFERENT FLUOROSCOPIC IMAGING CONDITIONS

被引:42
作者
BOONE, JM
LEVIN, DC
机构
[1] Department of Radiology, 3607 Gibbon Bldg., Thomas Jefferson University, Philadelphia, PA 19107
关键词
ANGIOGRAPHY; TECHNOLOGY; FLUOROSCOPY; PHANTOMS; RADIATIONS; INJURIOUS EFFECTS; GENETIC; GONADAL; MEASUREMENT;
D O I
10.1148/radiology.180.3.1871307
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
Radiation levels near an imaging chain commonly used in angiography were measured with both a 100-and a 200-mm-thick scatter phantom. The scatter was measured in lines parallel in space to the central ray of the x-ray beam, at lateral distances of 300, 500, and 800 mm. The effects of fluoroscopic kilovoltage and image intensifier magnification mode were also measured. The results indicate that the highest scattered radiation levels occur near the surface of the patient where the x-ray beam enters. Exposure rates were measured in both anteroposterior (AP) and posteroanterior (PA) geometries on a U-arm system. In PA geometry, the highest radiation levels occur below the angiographer's waist, an area well protected by the lead apron. The AP geometry increases the exposure rate to the neck, head, and upper extremities, areas where apron shielding is less effective.
引用
收藏
页码:861 / 865
页数:5
相关论文
共 13 条
[1]
RADIATION EXPOSURE TO PERSONNEL DURING CARDIAC CATHETERIZATION [J].
ARDRAN, GM ;
FURSDON, PS .
RADIOLOGY, 1973, 106 (03) :517-518
[2]
RADIATION-DOSE TO PERSONNEL DURING PERCUTANEOUS RENAL CALCULUS REMOVAL [J].
BUSH, WH ;
JONES, D ;
BRANNEN, GE .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1985, 145 (06) :1261-1264
[3]
THE CASE FOR RADIOPROTECTIVE EYEWEAR FACEWEAR - PRACTICAL IMPLICATIONS AND SUGGESTIONS [J].
COUSIN, AJ ;
LAWDAHL, RB ;
CHAKRABORTY, DP ;
KOEHLER, RE .
INVESTIGATIVE RADIOLOGY, 1987, 22 (08) :688-692
[4]
EXPOSURE OF RADIOLOGISTS TO SCATTERED RADIATION DURING RADIODIAGNOSTIC EXAMINATIONS [J].
KAN, K ;
SANTEN, BC ;
VELTHUYSE, HJM ;
JULIUS, HW .
RADIOLOGY, 1976, 119 (02) :455-457
[5]
LIN PPJ, 1985, RECENT DEV DIGITAL I, P464
[6]
RADIATION EXPOSURE TO PERSONNEL DURING CARDIAC CATHETERIZATION - PRELIMINARY STUDY [J].
MALSKY, SJ ;
ROSWIT, B ;
REID, CB ;
HAFT, J .
RADIOLOGY, 1971, 100 (03) :671-&
[7]
MCGUIRE EL, 1983, HEALTH PHYS, V45, P975, DOI 10.1097/00004032-198311000-00003
[8]
MILLER ME, 1983, J BONE JOINT SURG AM, V65, P1
[9]
Rosenstein M, 1976, ORGAN DOSES DIAGNOST
[10]
EXPOSURE OF RADIOLOGIST TO SCATTERED RADIATION DURING ANGIOGRAPHY [J].
SANTEN, BC ;
KAN, K ;
VELTHUYSE, HJM ;
JULIUS, HW .
RADIOLOGY, 1975, 115 (02) :447-450