CARBON-ENHANCED INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRIC DETECTION OF ARSENIC AND SELENIUM AND ITS APPLICATION TO ARSENIC SPECIATION

被引:317
作者
LARSEN, EH
STURUP, S
机构
关键词
ARSENIC; SELENIUM; METHANOL-ENHANCED SENSITIVITY; HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY INDUCTIVELY COUPLED PLASMA MASS SPECTROMETRY; ARSENIC SPECIATION IN SHRIMP;
D O I
10.1039/ja9940901099
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Addition of carbon as methanol or ammonium carbonate to the aqueous analyte solutions in combination with increased plasma power input enhanced the inductively coupled plasma mass spectrometry (ICP-MS) signal intensities of arsenic and selenium. In the presence of the optimum 3% v/v methanol concentration the signal intensities achieved were about 4500-5000 counts s-1 per ng ml-1 of arsenic and about 700-1100 counts s-1 per ng ml-1 of selenium (Se-82), corresponding to enhancement factors of 3.5-4.5 compared with aqueous solution for the two elements. Differences in sensitivity (calculated on the basis of analyte atom) were observed between the individual arsenic species and between the selenium species in aqueous as well as in carbon-added solutions. The presence of 3% v/v methanol in the analyte solutions doubled the level of the background signal for arsenic and selenium, but its fluctuation (noise) was not increased. Therefore, the observed increase in analyte sensitivity led to a similar increase in signal-to-noise ratio. The addition of carbon as ammonium carbonate enhanced the arsenic signal by a similar factor but caused severe contamination of the ICP-MS instrument by carbon. In the 3% v/v methanol solutions of arsenic and selenium the signal intensity from antimony (internal standard) was enhanced by a factor of 1.5, which indicates that the enhancement effect of the arsenic and selenium signals by methanol is only to a limited extent caused by improved sample transport/nebulization efficiency. It is proposed that an increased population of carbon ions or carbon-containing ions in the plasma facilitates a more complete ionization of analytes lower in ionization energy than carbon itself. The enhanced detection power for arsenic was applied to arsenic speciation by high-performance liquid chromatography (HPLC)-ICP-MS, and made possible the detection of the arsenocholine ion (AsC) in extracts of shrimp at the 5-10 ng g-1 concentration level. The limit of detection was improved by a factor of 3.4 after addition of methanol and was 4.7 ng g-1 as the AsC ion.
引用
收藏
页码:1099 / 1105
页数:7
相关论文
共 27 条
[1]   SIGNAL ENHANCEMENT OF ELEMENTS DUE TO THE PRESENCE OF CARBON-CONTAINING COMPOUNDS IN INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
ALLAIN, P ;
JAUNAULT, L ;
MAURAS, Y ;
MERMET, JM ;
DELAPORTE, T .
ANALYTICAL CHEMISTRY, 1991, 63 (14) :1497-1498
[2]   DETERMINATION OF ARSENIC SPECIES BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY - INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
BEAUCHEMIN, D ;
SIU, KWM ;
MCLAREN, JW ;
BERMAN, SS .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1989, 4 (03) :285-289
[3]   INVESTIGATIONS ON MIXED-GAS PLASMAS PRODUCED BY ADDING NITROGEN TO THE PLASMA GAS IN ICP-MS [J].
BEAUCHEMIN, D ;
CRAIG, JM .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1991, 46 (05) :603-614
[4]   DETERMINATION OF ARSENIC IN SAMPLES WITH HIGH CHLORIDE CONTENT BY INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
BRANCH, S ;
EBDON, L ;
FORD, M ;
FOULKES, M ;
ONEILL, P .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1991, 6 (02) :151-154
[5]   INFLUENCE OF CHEMICAL-SPECIES ON THE DETERMINATION OF MERCURY IN A BIOLOGICAL MATRIX (COD MUSCLE) USING INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
CAMPBELL, MJ ;
VERMEIR, G ;
DAMS, R ;
QUEVAUVILLER, P .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1992, 7 (04) :617-621
[6]  
CAMPBELL MJ, 1994, UNPUB J ANAL AT SPEC
[7]   INTERFERENCES IN INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY - A REVIEW [J].
EVANS, EH ;
GIGLIO, JJ .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1993, 8 (01) :1-18
[8]   EFFECT OF ORGANIC-SOLVENTS AND MOLECULAR GASES ON POLYATOMIC ION INTERFERENCES IN INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
EVANS, EH ;
EBDON, L .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1990, 5 (06) :425-429
[9]   ELIMINATION OF INTERFERENCES IN THE DETERMINATION OF ARSENIC AND SELENIUM IN BIOLOGICAL SAMPLES BY INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRY [J].
GOOSSENS, J ;
VANHAECKE, F ;
MOENS, L ;
DAMS, R .
ANALYTICA CHIMICA ACTA, 1993, 280 (01) :137-143
[10]   INDUCTIVELY COUPLED PLASMA SOURCE-MASS SPECTROMETRY USING CONTINUUM FLOW ION EXTRACTION [J].
GRAY, AL ;
DATE, AR .
ANALYST, 1983, 108 (1290) :1033-1050