TUNGSTEN SENSOR FOR AMPEROMETRIC DETECTION OF ORGANIC THIOLS AND PROTEINS

被引:22
作者
ALEXANDER, PW
HIDAYAT, A
HIBBERT, DB
机构
[1] Department of Analytical Chemistry, University of New South Wales, Sydney, New South Wales
关键词
THIOLS; TUNGSTEN SENSOR; AMPEROMETRIC DETECTION;
D O I
10.1002/elan.1140070318
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An amperometric sensor constructed with a metallic tungsten wire is reported for the indirect detection of organic thiols and proteins. Cysteine added to mercury(Ir) (40.0 mu M) buffered in 5.0 mM sodium acetate at pH 4.7 causes a decrease in the reduction current of mercury at -0.2 V (vs. SCE). Detection limits were found to be in the range 0.05-0.2 mu g/mL for cysteine, thiourea and glutathione, but were poorer for albumin and DNA, showing this method is relatively selective for cysteine. The advantages of the tungsten electrode are its low cost, miniature size, and its inert oxide surface which does not amalgamate with mercury.
引用
收藏
页码:290 / 291
页数:2
相关论文
共 16 条
[1]   AUTOMATED CONTINUOUS-FLOW DETERMINATIONS OF SERUM-PROTEINS BY PULSE POLAROGRAPHY [J].
ALEXANDER, PW ;
SHAH, MH .
TALANTA, 1979, 26 (02) :97-102
[2]   POTASSIUM TITANIUM(IV) OXALATE AS A REAGENT FOR AUTOMATED PULSE POLAROGRAPHIC-DETERMINATION OF SEROMUCOIDS [J].
ALEXANDER, PW ;
SHAH, MH .
ANALYTICAL CHEMISTRY, 1979, 51 (13) :2139-2143
[3]   AMPEROMETRIC DETERMINATION OF METAL-IONS IN A FLOW-INJECTION SYSTEM WITH A COPPER-AMALGAM ELECTRODE [J].
ALEXANDER, PW ;
AKAPONGKUL, U .
ANALYTICA CHIMICA ACTA, 1983, 148 (APR) :103-109
[4]  
ALEXANDER PW, 1984, ANAL CHIM ACTA, V166, P119
[5]   AMPEROMETRY OF THIOLS IN A FLOW-INJECTION SYSTEM WITH A NICKEL-OXIDE ELECTRODE [J].
ARIKAWA, Y ;
HUBER, CO .
ANALYTICA CHIMICA ACTA, 1990, 229 (02) :191-195
[6]   DETERMINATION OF AROMATIC AND SULFUR-CONTAINING AMINO-ACIDS, PEPTIDES, AND PROTEINS USING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH PHOTOLYTIC ELECTROCHEMICAL DETECTION [J].
DOU, L ;
KRULL, IS .
ANALYTICAL CHEMISTRY, 1990, 62 (23) :2599-2606
[7]   ELECTROCHEMICAL FLOW-THROUGH DETECTOR FOR DETERMINATION OF CYSTINE AND RELATED COMPOUNDS [J].
EGGLI, R ;
ASPER, R .
ANALYTICA CHIMICA ACTA, 1978, 101 (02) :253-259
[8]   CATHODIC STRIPPING VOLTAMMETRIC BEHAVIOR OF CYSTEINE AND CYSTINE IN THE PRESENCE OF CUPRIC IONS [J].
FORSMAN, U .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1981, 122 (MAY) :215-231
[9]  
FORSMAN U, 1984, ANAL CHIM ACTA, V100, P141
[10]   ELECTROCATALYTIC AND ANALYTICAL RESPONSE OF COBALT PHTHALOCYANINE CONTAINING CARBON PASTE ELECTRODES TOWARD SULFHYDRYL COMPOUNDS [J].
HALBERT, MK ;
BALDWIN, RP .
ANALYTICAL CHEMISTRY, 1985, 57 (03) :591-595