DETERMINATION OF NH3 IN PYROLYSIS GASES BY AMMONIA SELECTIVE ELECTRODE

被引:6
作者
HAMALAINEN, JP [1 ]
TUMMAVUORI, JL [1 ]
AHO, MJ [1 ]
机构
[1] UNIV JYVASKYLA,DEPT CHEM,SF-40100 JYVASKYLA,FINLAND
关键词
D O I
10.1016/0039-9140(93)80371-W
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The suitability of ion-selective electrode for the determination of ammonia in pyrolysis gases of fossil fuels was studied. The ammonia was absorbed into acidic solution and two kinds of determination methods were carried out. The ammonia was either measured directly from the acid solution, or ammonia was first released into the gas phase and then determined (air gap method) by the ammonia selective electrode. The electrode functioned well in both cases, but the linear calibration range was rather narrow, slightly more than one tenfold. The quantitative detection limit in the water phase was 5 x 10(-6)M (0.085 ppm) NH3 and in gas phase operation solutions above 5 x 10(-4)M (8.5 ppm) NH3 it WaS possible to measure quantitatively. The applications were carried out with Finnish energy peat samples and a coal sample.
引用
收藏
页码:1575 / 1581
页数:7
相关论文
共 15 条
[1]  
AHO M, 1989, FUEL, V68, P585
[2]  
AHO MJ, UNPUB FUEL
[3]  
AHO MJ, UNPUB COMBUSTION FLA
[4]  
BURDETT NA, 1987, 1987 INT C COAL SCI, P845
[5]   POROUS MEMBRANE-BASED DIFFUSION SCRUBBER FOR THE SAMPLING OF ATMOSPHERIC GASES [J].
DASGUPTA, PK ;
MCDOWELL, WL ;
RHEE, JS .
ANALYST, 1986, 111 (01) :87-90
[6]  
GENFA Z, 1989, ENVIRON SCI TECHNOL, V23, P1467, DOI 10.1021/es00070a003
[7]  
KELLY MD, 1991, INT C COAL SCI, P356
[8]   MEASUREMENT OF ATMOSPHERIC SULFUR-DIOXIDE BY DIFFUSION SCRUBBER COUPLED ION CHROMATOGRAPHY [J].
LINDGREN, PF ;
DASGUPTA, PK .
ANALYTICAL CHEMISTRY, 1989, 61 (01) :19-24
[9]  
MILLER JC, 1984, STATISTICAL ANAL CHE, V1, P56
[10]   CONVERSION OF FUEL NITROGEN IN COAL VOLATILES TO NOX PRECURSORS UNDER RAPID HEATING CONDITIONS [J].
NELSON, PF ;
KELLY, MD ;
WORNAT, MJ .
FUEL, 1991, 70 (03) :403-407