THE DESIGN AND PHYSICAL CHARACTERISTICS OF A SMALL ANIMAL POSITRON EMISSION TOMOGRAPH

被引:127
作者
BLOOMFIELD, PM
RAJESWARAN, S
SPINKS, TJ
HUME, SP
MYERS, R
ASHWORTH, S
CLIFFORD, KM
JONES, WF
BYARS, LG
YOUNG, J
ANDREACO, M
WILLIAMS, CW
LAMMERTSMA, AA
JONES, T
机构
[1] CTI,PET SYST,KNOXVILLE,TN
[2] BYARS CONSULTING,OAK RIDGE,TN
关键词
D O I
10.1088/0031-9155/40/6/010
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A small diameter positron emission tomograph, designed specifically for small animal studies, was constructed from existing, commercially available, bismuth germanate (EGO) detectors and electronics. The scanner consists of 16 EGO detector blocks arranged to give a tomograph with a diameter of 115 mm and an axial field of view (FOV) of 50 mm. Each block is cut to produce eight (axial) by seven (radial) individual detector elements. The absence of interplane septa enables the acquisition of 3D data sets consisting of 64 sinograms. A 2D, data set of 15 sinograms, consisting of eight direct and seven adjacent cross planes, can be extracted from the 3D data set. Images are reconstructed from the 20 sinograms using a conventional filtered backprojection algorithm. Two methods of normalization were investigated, based on either a rotating Ge-68 rod source, or a uniform Ge-68 plane source, with a uniform cylindrical F-18 phantom. Attenuation of the emitted photons was estimated using a rotating Ge-68 rod source. The transaxial resolution of the tomograph was measured as 2.3 mm full width at half maximum (FWHM) and 5.6 mm full width at tenth maximum (FWTM) at the centre of the FOV, degrading to 6.6 mm (radial) and 4.4 mm (tangential) FWHM and 10.4 mm (radial) and 14.4 mm (tangential) FWTM at 40.0 mm from the centre of the Fov. The axial slice width was 4.3 mm FWHM, 10.3 mm FWTM at the centre of the transaxial field of view and 4.4 mm FWHM, 10.6 mm FWTM at 20.0 mm from the centre of the FOV. A scatter fraction of 31.0% was measured at 250-850 keV, for an F-18 line source centred in a 60 mm diameter, water-filled phantom, reducing to 20.4% and 13.8% as the lower energy discrimination was increased to 380 keV and 450 keV, respectively. The count rate performance was measured using a noise equivalent count rate method, and the linearity of the dead time correction was confirmed over the count rates encountered during routine scanning. In 20 mode, the absolute sensitivity of the tomograph was measured as 9948 counts s(-1) MBq(-1) at 250-850 keV, 8284 counts s(-1) MBq(-1) at 380-850 keV and 6280 counts s(-1) MBq(-1) at 450-850 keV.
引用
收藏
页码:1105 / 1126
页数:22
相关论文
共 16 条
  • [1] A CONVOLUTION-SUBTRACTION SCATTER CORRECTION METHOD FOR 3D PET
    BAILEY, DL
    MEIKLE, SR
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1994, 39 (03) : 411 - 424
  • [2] BAILEY DL, 1991, EUR J NUCL MED, V19, P374
  • [3] CASEY ME, 1986, IEEE T NUCL SCI, V33, P570
  • [4] CUTLER PD, 1992, J NUCL MED, V33, P595
  • [6] GROOTOONK S, 1992, 1992 IEEE MED IMAG C, V2, P942
  • [7] PET SYSTEM CALIBRATIONS AND CORRECTIONS FOR QUANTITATIVE AND SPATIALLY ACCURATE IMAGES
    HOFFMAN, EJ
    GUERRERO, TM
    GERMANO, G
    DIGBY, WM
    DAHLBOM, M
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1989, 36 (01) : 1108 - 1112
  • [8] HUBBEL JH, 1969, NRSDSNBS29 PUBL
  • [9] QUANTITATION OF CARBON-11-LABELED RACLOPRIDE IN RAT STRIATUM USING POSITRON EMISSION TOMOGRAPHY
    HUME, SP
    MYERS, R
    BLOOMFIELD, PM
    OPACKAJUFFRY, J
    CREMER, JE
    AHIER, RG
    LUTHRA, SK
    BROOKS, DJ
    LAMMERTSMA, AA
    [J]. SYNAPSE, 1992, 12 (01) : 47 - 54
  • [10] RAPID FEASIBILITY STUDIES OF TRACERS FOR POSITRON EMISSION TOMOGRAPHY - HIGH-RESOLUTION PET IN SMALL ANIMALS WITH KINETIC-ANALYSIS
    INGVAR, M
    ERIKSSON, L
    ROGERS, GA
    STONEELANDER, S
    WIDEN, L
    [J]. JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1991, 11 (06) : 926 - 931