POTASSIUM-SELECTIVE OPTRODE BASED ON AN IMMOBILIZED FLUOROGENIC CROWN-ETHER

被引:9
作者
DIAZGARCIA, ME [1 ]
ALAVAMORENO, F [1 ]
SANZMEDEL, A [1 ]
机构
[1] UNIV OVIEDO,DEPT PHYS & ANALYT CHEM,JULIAN CLAVERIA 8,E-33006 OVIEDO,SPAIN
关键词
POTASSIUM; FLUOROGENIC CROWN ETHERS; OPTICAL SENSORS; HUMAN SERUM; URINE;
D O I
10.1007/BF01243612
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new optical sensor phase for potassium ions has been developed based on the immobilization of the pH-dependent fluorogenic crown ether 4-acryloylamidobenzo-18-crown-6 on the non-ionic polymeric resin Amberlite XAD-2. Two different optical designs, a flow-through sensor and a fibre optic probe-type sensor (optrode), have been constructed and their analytical performance characteristics have been evaluated. The resulting fluorimetric sensors for K+ ions exhibited detection limits of 0.4 or 0.8 muM of K+ (16 mug/l or 31 mug/l), depending on the design, while the linear response occurred from 1 to 25 muM of the metal concentrations. The precision, evaluated as the relative standard deviation of measurements of K+ levels at around ten times the detection limit (e.g. 5 muM), turned out to be around +/-2%. Advantageous features of this fluorimetric sensing phase and optrode include ease of construction, simplicity of use, reversibility, short response times (ca. 1 min full scale deflection) selectivity and operational stability, suitable for sensing potassium at low levels in complex matrices such as biological fluids. The fluorimetric optical sensor has been successfully applied to the direct determination of potassium in clinically important samples (serum and urine) and in natural waters. Very good accuracy has been obtained just using adequate synthetic aqueous potassium standards for calibration.
引用
收藏
页码:211 / 222
页数:12
相关论文
共 29 条
[1]   SYNTHESIS AND CHARACTERIZATION OF SOME CHROMOGENIC CROWN ETHERS AS POTENTIAL OPTICAL SENSORS FOR POTASSIUM-IONS [J].
ALAMIR, SMS ;
ASHWORTH, DC ;
NARAYANASWAMY, R ;
MOSS, RE .
TALANTA, 1989, 36 (06) :645-650
[2]   A COMPARATIVE-STUDY OF 2 DIFFERENT APPROACHES FOR ACTIVE OPTICAL SENSING OF POTASSIUM WITH A CHROMOIONOPHORE [J].
ALAVAMORENO, F ;
PEREIROGARCIA, R ;
DIAZGARCIA, ME ;
SANZMEDEL, A .
SENSORS AND ACTUATORS B-CHEMICAL, 1993, 11 (1-3) :413-419
[3]   AN OPTICAL POTASSIUM-ION SENSOR [J].
ALDER, JF ;
ASHWORTH, DC ;
NARAYANASWAMY, R ;
MOSS, RE ;
SUTHERLAND, IO .
ANALYST, 1987, 112 (08) :1191-1192
[4]   AN OPTICAL CALCIUM-ION SENSOR [J].
ASHWORTH, DC ;
HUANG, HP ;
NARAYANASWAMY, R .
ANALYTICA CHIMICA ACTA, 1988, 213 (1-2) :251-257
[5]  
CHARLTON SC, 1982, CLIN CHEM, V28, P1857
[6]   SERUM ANALYSIS FOR POTASSIUM-IONS USING A FIBER OPTIC SENSOR [J].
GARCIA, RP ;
MORENO, FA ;
GARCIA, MED ;
SANZMEDEL, A ;
NARAYANASWAMY, R .
CLINICA CHIMICA ACTA, 1992, 207 (1-2) :31-40
[7]   NOVEL TYPE OF ION-SELECTIVE FLUOROSENSOR BASED ON THE INNER FILTER EFFECT - AN OPTRODE FOR POTASSIUM [J].
HE, HR ;
LI, H ;
MOHR, G ;
KOVACS, B ;
WERNER, T ;
WOLFBEIS, OS .
ANALYTICAL CHEMISTRY, 1993, 65 (02) :123-127
[8]   FIBEROPTIC POTASSIUM-ION SENSOR USING ALKYL-ACRIDINE ORANGE IN PLASTICIZED POLY(VINYL CHLORIDE) MEMBRANE [J].
KAWABATA, Y ;
TAHARA, R ;
KAMICHIKA, T ;
IMASAKA, T ;
ISHIBASHI, N .
ANALYTICAL CHEMISTRY, 1990, 62 (14) :1528-1531
[9]   FLUOROMETRIC-DETERMINATION OF POTASSIUM-ION USING HEXADECYL-ACRIDINE ORANGE IMMOBILIZED ON A POLY(VINYL CHLORIDE) MEMBRANE ATTACHED TO A FLOW-THROUGH CELL [J].
KAWABATA, Y ;
IMASAMA, T ;
ISHIBASHI, N .
ANALYTICA CHIMICA ACTA, 1991, 255 (01) :97-101
[10]  
KUMAR A, 1988, CLIN CHEM, V34, P1709