CLINICAL COMPARISON OF THE PROTON AND TONO-PEN TONOMETERS WITH THE GOLDMANN APPLANATION TONOMETER

被引:39
作者
MIDELFART, A
WIGERS, A
机构
[1] Department of Ophthalmology, Faculty of Medicine, University of Trondheim
关键词
D O I
10.1136/bjo.78.12.895
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
A clinical evaluation of a new electron ProTon tonometer was performed comparing the values of intraocular pressure (IOP) measured using this instrument with those determined by a similar instrument, Tone-Pen XL, and by Goldmann applanation tonometry. The mean IOP measured in 106 eyes with the ProTon tonometer was not significantly different from that determined with Goldmann applanation, while the IOP values measured with Tone-Pen XL were significantly lower. The 95% limits of agreement between applanation tonometry and ProTon tonometry were between -4 mm Hg and 5 mm Hg and between applanation tonometry and Tone-Pen XL tonometry between -3 mm Hg and 8 mm Hg. The ProTon tonometer appears to have a higher level of accuracy than the Tone-Pen XL tonometer in clinical practice.
引用
收藏
页码:895 / 898
页数:4
相关论文
共 16 条
[1]   EVALUATION OF THE TONO-PEN AND THE PULSAIR TONOMETERS [J].
ARMSTRONG, TA .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1990, 109 (06) :716-720
[2]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]   THE TONO-PEN - A MANOMETRIC AND CLINICAL-STUDY [J].
BOOTHE, WA ;
LEE, DA ;
PANEK, WC ;
PETTIT, TH .
ARCHIVES OF OPHTHALMOLOGY, 1988, 106 (09) :1214-1217
[4]  
CHRISTOFFERSEN T, 1993, ACTA OPHTHALMOL, V71, P103
[5]   EVALUATION OF THE TONO-PEN-2 AND THE X-PERT(TM) NONCONTACT TONOMETERS IN CATARACT-SURGERY [J].
DENIS, P ;
NORDMANN, JP ;
BERTIN, V ;
GAYRAUD, JM ;
LAROCHE, L ;
SARAUX, H .
OPHTHALMOLOGICA, 1993, 207 (03) :155-161
[6]   AN EVALUATION OF THE TONO-PEN FOR THE MEASUREMENT OF DIURNAL INTRAOCULAR-PRESSURE [J].
FARRAR, SM ;
MILLER, KN ;
SHIELDS, MB ;
STOUP, CM .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1989, 107 (04) :411-416
[7]   TONO-PEN TONOMETRY IN NORMAL AND IN POSTKERATOPLASTY EYES [J].
GEYER, O ;
MAYRON, Y ;
LOEWENSTEIN, A ;
NEUDORFER, M ;
ROTHKOFF, L ;
LAZAR, M .
BRITISH JOURNAL OF OPHTHALMOLOGY, 1992, 76 (09) :538-540
[8]   COMPARISON OF INTRAOCULAR-PRESSURE MEASUREMENTS WITH THE OCULAB TONO-PEN VS MANOMETRY IN HUMANS SHORTLY AFTER DEATH [J].
HESSEMER, V ;
ROSSLER, R ;
JACOBI, KW .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1988, 105 (06) :678-682
[9]   CLINICAL-EVALUATION OF THE OCULAB TONO-PEN [J].
HIGGINBOTHAM, EJ .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1988, 105 (01) :101-101
[10]  
HINES MW, 1988, AM J OPHTHALMOL, V106, P174