FINITE-DIFFERENCE CALCULATIONS OF CURRENT DENSITIES IN A HOMOGENEOUS MODEL OF A MAN EXPOSED TO EXTREMELY LOW-FREQUENCY ELECTRIC-FIELDS

被引:22
作者
DIMBYLOW, PJ
机构
关键词
D O I
10.1002/bem.2250080405
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
This paper presents three-dimensional finite difference calculations of induced current densities in a grounded, homogeneous, realistically human-shaped phantom. Comparison is made with published experimental values of current density at 60 Hz, measured in conducting saline manikins with their arms down by the side. The congruence between calculation and experiment gives confidence in the applicability of the numerical method and phantom shape to other configurations. The effect of raising both arms above the head is to reduce the current densities in the head and neck by .apprx. 50% and to increase those from the thorax downwards by 20-30%. A sensitivity analysis was performed on the shape and dimensions of the phantom, from a 45-kg, 1.5-m-tall person to a 140-kg, 1.9-m-tall person. When the phantom is grounded through both feet the current densities range from 50 to 90 .mu.Am-2 in the head (all values for a 60-Hz, 1-kVm-1, vertical applied field), 70 to 140 .mu.Am-2 in the thorax, 150 to 440 .mu.Am-2 at the crotch, and 500 to 2,230 .mu.Am-2 in the ankle. When grounded through only one foot the current densities at the crotch range from 400 to 1,000 .mu.Am-2 and from 1,000 to 4,400 .mu.Am-2 in the ankle of the grounded leg. Scale transformations of the short-circuit current with phamtom height, weight, and surface area are confirmed.
引用
收藏
页码:355 / 375
页数:21
相关论文
共 14 条
[1]   QUANTIFICATION OF INTERACTION BETWEEN ELF-LF ELECTRIC-FIELDS AND HUMAN BODIES [J].
CHEN, KM ;
CHUANG, HR ;
LIN, CJ .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1986, 33 (08) :746-756
[2]   APPLICATION OF FINITE-ELEMENT METHOD TO ANALYSIS OF INDUCED CURRENT DENSITIES INSIDE HUMAN-MODEL EXPOSED TO 60-HZ ELECTRIC-FIELD [J].
CHIBA, A ;
ISAKA, K ;
YOKOI, Y ;
NAGATA, M ;
KITAGAWA, M ;
MATSUO, T .
IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1984, 103 (07) :1895-1902
[3]   CURRENTS INDUCED IN HUMAN-BODY BY HIGH-VOLTAGE TRANSMISSION-LINE ELECTRIC-FIELD - MEASUREMENT AND CALCULATION OF DISTRIBUTION AND DOSE [J].
DENO, DW .
IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1977, 96 (05) :1517-1527
[4]  
DIMBYLOW PJ, 1986, 1986 P URSI S EL THE, P243
[5]  
EDWARDS NA, 1985, 1985 P C EL MAGN FIE
[6]   LIKELIHOOD OF HIGH-RATES OF ENERGY DEPOSITION IN THE HUMAN LEGS AT THE ANSI RECOMMENDED 3-30-MHZ RF SAFETY LEVELS [J].
GANDHI, OP ;
CHATTERJEE, I ;
WU, D ;
GU, YG .
PROCEEDINGS OF THE IEEE, 1985, 73 (06) :1145-1147
[7]  
HART F X, 1982, Journal of Bioelectricity, V1, P129
[9]   NUMERICAL-CALCULATION AND MEASUREMENT OF 60-HZ CURRENT DENSITIES INDUCED IN AN UPRIGHT GROUNDED CYLINDER [J].
KAUNE, WT ;
MCCREARY, FA .
BIOELECTROMAGNETICS, 1985, 6 (03) :209-220
[10]   CURRENT DENSITIES MEASURED IN HUMAN MODELS EXPOSED TO 60-HZ ELECTRIC-FIELDS [J].
KAUNE, WT ;
FORSYTHE, WC .
BIOELECTROMAGNETICS, 1985, 6 (01) :13-32