MEASUREMENT OF PEPTIDOLEUKOTRIENES IN BIOLOGICAL-FLUIDS

被引:64
作者
WESTCOTT, JY
JOHNSTON, K
BATT, RA
WENZEL, SE
VOELKEL, NF
机构
[1] NATL JEWISH CTR IMMUNOL & RESP MED, DENVER, CO 80206 USA
[2] UNIV COLORADO, HLTH SCI CTR, WEBB WARING LUNG INST, DENVER, CO 80262 USA
关键词
adult respiratory distress syndrome; asthma; bronchoalveolar lavage fluid; enzyme immunoassay; leukotrienes; urine;
D O I
10.1152/jappl.1990.68.6.2640
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Samples of human bronchoalveolar lavage fluid (BALF) and urine were utilized to demonstrate methods for quantitation and validation of leukotrienes (LTs). These methods utilize an enzyme immunoassay (EIA) that uses commercially available reagents, the antibody recognizing LTC4, LTD4, LTE4 and N-acetyl LTE4. BALF containing epithelial lining fluid was collected from atopic asthmatics both before and 5 min after the subjects had been challenged with a local instillation of allergen into the airways. BALF samples collected without allergen challenge had low levels of immunoreactive LTs, whereas samples collected after allergen were markedly elevated. After high-performance liquid chromatography (HPLC) separation of LTs, EIA revealed the presence of LTC4 with a bovine γ-glutamyl transpeptidase with dipeptidase activity that converted added [3H]LTC4 as well as LTC4 immunoreactivity to LTE4. Urine samples collected from six healthy volunteers, one patient with adult respiratory distress syndrome (ARDS), and three patients in status asthmaticus were also analyzed for LTs. After HPLC separation of LTs and quantitation by EIA, urine samples from healthy subjects were found to have low but measurable LTE4. In contrast, the urine samples from the patients in status asthmaticus and from the ARDS patient had large elevations of LTE4 levels compared with healthy subjects. When the HPLC fractions containing [3H]LTE4 and LT immunoreactivity in the ARDS sample were treated with acetic anhydride, HPLC analysis indicated that both radiolabel and immunoreactivity now eluted at the retention time of N-acetyl LTE4, the derivatized product of LTE4. The methods described are relatively easy and can be used to measure and validate the existence of peptidoleukotrienes in biological samples.
引用
收藏
页码:2640 / 2648
页数:9
相关论文
共 32 条
[1]   DETERMINATION OF SULFIDOPEPTIDE LEUKOTRIENES IN BIOLOGICAL-FLUIDS BY GAS-CHROMATOGRAPHY MASS-SPECTROMETRY [J].
BALAZY, M ;
MURPHY, RC .
ANALYTICAL CHEMISTRY, 1986, 58 (06) :1098-1101
[2]   OMEGA-OXIDATION PRODUCTS OF LEUKOTRIENE-E4 IN BILE AND URINE OF THE MONKEY [J].
BALL, HA ;
KEPPLER, D .
BIOCHEMICAL AND BIOPHYSICAL RESEARCH COMMUNICATIONS, 1987, 148 (02) :664-670
[3]   STABILITY OF LEUKOTRIENES C-4 AND D4 IN HUMAN-URINE [J].
BEYER, G ;
MEESE, CO ;
KLOTZ, U .
PROSTAGLANDINS LEUKOTRIENES AND MEDICINE, 1987, 29 (2-3) :229-235
[4]   LEUKOTRIENES AS MEDIATORS IN TISSUE TRAUMA [J].
DENZLINGER, C ;
RAPP, S ;
HAGMANN, W ;
KEPPLER, D .
SCIENCE, 1985, 230 (4723) :330-332
[5]   LEUKOTRIENES AND AIRWAY RESPONSES [J].
DRAZEN, JM ;
AUSTEN, KF .
AMERICAN REVIEW OF RESPIRATORY DISEASE, 1987, 136 (04) :985-998
[6]  
FOSTER A, 1988, J IMMUNOL, V141, P3544
[7]  
HAMMARSTROM S, 1988, ANN NY ACAD SCI, V524, P43
[8]   LEUKOTRIENE-C4, LEUKOTRIENE-D4 AND LEUKOTRIENE-E4 CAUSE WIDESPREAD AND EXTENSIVE PLASMA EXTRAVASATION IN THE GUINEA-PIG [J].
HUA, XY ;
DAHLEN, SE ;
LUNDBERG, JM ;
HAMMARSTROM, S ;
HEDQVIST, P .
NAUNYN-SCHMIEDEBERGS ARCHIVES OF PHARMACOLOGY, 1985, 330 (02) :136-141
[9]   ANALYSIS OF CYSTEINYL LEUKOTRIENES IN HUMAN-URINE - ENHANCED EXCRETION IN PATIENTS WITH LIVER-CIRRHOSIS AND HEPATORENAL-SYNDROME [J].
HUBER, M ;
KASTNER, S ;
SCHOLMERICH, J ;
GEROK, W ;
KEPPLER, D .
EUROPEAN JOURNAL OF CLINICAL INVESTIGATION, 1989, 19 (01) :53-60
[10]  
KEPPLER D, 1988, ANN NY ACAD SCI, V524, P68