CORRELATION OF PROJECTION RADIOGRAPHS IN RADIATION-THERAPY USING OPEN CURVE SEGMENTS AND POINTS

被引:88
作者
BALTER, JM
PELIZZARI, CA
CHEN, GTY
机构
关键词
IMAGE REGISTRATION; PORTAL FILMS; OPEN CURVES;
D O I
10.1118/1.596863
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A method for determining differences in patient position between projection radiographs such as those routinely used in radiation therapy has been developed. Determination of a transformation relating two radiographs permits registration of simulation and portal images and the transfer of information between them. The algorithm is based on spatially registering segments of open curves or points seen on both images, and does not require identification of corresponding curve endpoints. The method as implemented is both fast and accurate. After user definition of the curves or points to be registered, the optimal transformation is calculated in approximately 1 s. Calculational experiments indicate that corresponding points on open curves are registered to better than 2 mm, even when random errors (FWHM 1 mm) in digitization are included. Experiments on the registration of clinical portal and simulation images (pixel size = 0.5 by 0.5 mm) indicate an accuracy on the order of 2 mm or less in translation and 2 deg or less in rotation. Analysis of portal and simulation radiographs of the brain, thorax, and pelvis indicates this algorithm to be robust and clinically applicable. The rapid and accurate registration of portal and simulation images is potentially important in the application of real time portal imaging devices in radiation therapy.
引用
收藏
页码:329 / 334
页数:6
相关论文
共 10 条
[1]  
EVANS AC, 1989, P SOC PHOTO-OPT INS, V1092, P264
[2]   CALCULATION OF THE UNCERTAINTY IN THE DOSE DELIVERED DURING RADIATION-THERAPY [J].
GOITEIN, M .
MEDICAL PHYSICS, 1985, 12 (05) :608-612
[3]   VISUALIZATION OF INTERNAL MOTION WITHIN A TREATMENT PORTAL DURING A RADIATION-THERAPY TREATMENT [J].
LEONG, JC ;
STRACHER, MA .
RADIOTHERAPY AND ONCOLOGY, 1987, 9 (02) :153-156
[4]   EFFECT OF IMMOBILIZATION ON LOCALIZATION ERROR IN RADIOTHERAPY OF HEAD AND NECK CANCER [J].
MARKS, JE ;
HAUS, AG .
CLINICAL RADIOLOGY, 1976, 27 (02) :175-177
[5]   A METHOD FOR THE MEASUREMENT OF FIELD PLACEMENT ERRORS IN DIGITAL PORTAL IMAGES [J].
MEERTENS, H ;
BIJHOLD, J ;
STRACKEE, J .
PHYSICS IN MEDICINE AND BIOLOGY, 1990, 35 (03) :299-323
[6]  
SCHONEMANN PH, 1970, PSYCHOMETRIKA, V35, P247
[7]   AUTOMATIC DIGITAL CONTRAST ENHANCEMENT OF RADIOTHERAPY FILMS [J].
SHEROUSE, GW ;
ROSENMAN, J ;
MCMURRY, HL ;
PIZER, SM ;
CHANEY, EL .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1987, 13 (05) :801-806
[8]   A MATRIX IONIZATION-CHAMBER IMAGING DEVICE FOR ONLINE PATIENT SETUP VERIFICATION DURING RADIOTHERAPY [J].
VANHERK, M ;
MEERTENS, H .
RADIOTHERAPY AND ONCOLOGY, 1988, 11 (04) :369-378
[9]   EVALUATION OF ANALOG CONTRAST ENHANCEMENT AND DIGITAL UNSHARP MASKING IN LOW-CONTRAST PORTAL IMAGES [J].
WEISER, JC ;
GUR, D ;
GENNARI, RC ;
DEUTSCH, M .
MEDICAL PHYSICS, 1990, 17 (01) :122-125
[10]  
WOLFSON H, 1987, NOV P IEEE COMP SOC, P307