SOURCE CONFIGURATION AND DOSE-RATES FOR THE SELECTRON AFTERLOADING EQUIPMENT FOR GYNECOLOGIC APPLICATORS

被引:15
作者
GRIGSBY, PW
WILLIAMSON, JF
PEREZ, CA
机构
[1] Mallinckrodt Institute of Radiology, Radiation Oncology Center, Washington University School of Medicine, St. Louis, MO
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 1992年 / 24卷 / 02期
关键词
BRACHYTHERAPY; REMOTE AFTERLOADING; IMPLANTS; RADIOTHERAPY;
D O I
10.1016/0360-3016(92)90688-E
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
This paper describes source train configurations of the Selectron LDR-6 that can be used to duplicate commonly used manually afterloadable source configurations for gynecological intracavitary brachytherapy. We demonstrate that the recommended source configuration using 2.5 mm Cs-137 spheres is dosimetrically equivalent to its manually afterloaded counterparts using 3M Cs-137 sources (20 mm overall length, 14 mm active length). Isodose distributions are in agreement to within 5% for the Fletcher-Suit-Delclos family of tandems, colpostats, and vaginal cylinders. Our data also demonstrate that the isotropic point source model used by most computerized treatment planning systems is a good approximation to source trains of filtered, spherical sources interspersed with solid steel spacers. We conclude that the use of 2.5 mm Cs-137 sources in the Selectron remote afterloading system can accurately reproduce the isodose distribution achieved with linear Cs-137 manually afterloaded sources.
引用
收藏
页码:321 / 327
页数:7
相关论文
共 14 条
[1]   GYNECOLOGICAL TREATMENTS USING THE SELECTRON REMOTE AFTERLOADING SYSTEM [J].
DEAN, EM ;
LAMBERT, GD ;
DAWES, PJDK .
BRITISH JOURNAL OF RADIOLOGY, 1988, 61 (731) :1053-1057
[2]   EXPERIMENTAL AND CALCULATED DOSE DISTRIBUTION IN WATER AROUND CDC K-TYPE CESIUM-137 SOURCES [J].
DIFFEY, BL ;
KLEVENHAGEN, SC .
PHYSICS IN MEDICINE AND BIOLOGY, 1975, 20 (03) :446-454
[3]   GEOMETRY ADOPTED BY MANCHESTER RADIUM APPLICATORS AND SELECTRON AFTERLOADING APPLICATORS IN INTRACAVITARY TREATMENT FOR CARCINOMA CERVIX UTERI [J].
JONES, DA ;
NOTLEY, HM ;
HUNTER, RD .
BRITISH JOURNAL OF RADIOLOGY, 1987, 60 (713) :481-485
[4]   DOSE DISTRIBUTIONS ABOUT CS-137 SOURCES IN TISSUE [J].
KRISHNASWAMY, V .
RADIOLOGY, 1972, 105 (01) :181-+
[5]  
MARBACH JR, 1985, BRACHYTHERAPY 1984, P255
[7]  
SAYLOR W L, 1976, Medical Physics (Woodbury), V3, P117, DOI 10.1118/1.594277
[8]   DOSE-RATES FOR BRACHYTHERAPY APPLICATORS USING CS-137 SOURCES [J].
SHARMA, SC ;
GERBI, B ;
MADOCJONES, H .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1979, 5 (10) :1893-1897
[9]   The fusion of intensity of primary gamma-ratiation around medical radium preparations [J].
Sievert, RM .
ACTA RADIOLOGICA, 1921, 1 :89-128
[10]  
VANDERLAARSE R, 1985, BRACHYTHERAPY 1984, P176