ADSORPTION OF RN-222 BY OPEN-FACED AND DIFFUSION-BARRIER CANISTERS AT DIFFERENT CONDITIONS OF TEMPERATURE AND HUMIDITY

被引:17
作者
LUETZELSCHWAB, JW
HASTINGS, L
ELLIS, SM
机构
[1] Department of Physics and Astronomy, Dickinson College, Carlisle, PA 17013-2896
来源
HEALTH PHYSICS | 1994年 / 66卷 / 01期
关键词
AIR SAMPLING; CHARCOAL CANISTERS; RN-222; MONITORS; RADON;
D O I
10.1097/00004032-199401000-00009
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Open-faced and diffusion-barrier charcoal canisters were individually exposed to a fixed temperature, humidity, and radon concentration in a chamber for a period of 7 d. The radon progeny activity in the canister under study was measured every 3 h. A total of 15 runs were made for the open-faced canisters and nine runs for the barrier canisters with temperatures and absolute humidities ranging from 15-30 degrees C and 0-15 g m(-3), respectively. In addition, several runs were made with the radon, temperature, and humidity changing during the 7 d. Results show that open-faced canisters adsorb radon up to 60% more efficiently at 15 degrees C than at 30 degrees C while the barrier canisters show little temperature dependence. The barrier canisters are much less sensitive to humidity effects than the open-faced canister. When used to measure the radon concentration in air, the open-faced canister integrates over a period of only similar to 48 h while the barrier canister integrates over a period of similar to 96 h. The short integration time and the interference of water adsorption by open-faced canisters indicate that the open-faced canisters should be used for exposure times of 48 h and no longer.
引用
收藏
页码:63 / 71
页数:9
相关论文
共 15 条
[1]  
BLUE TE, 1989, RADIAT PROT DOSIM, V27, P173
[2]  
BLUE TE, 1992, HEALTH PHYS, V62, P226
[3]   A DIFFUSION BARRIER CHARCOAL ADSORPTION COLLECTOR FOR MEASURING RN CONCENTRATIONS IN INDOOR AIR [J].
COHEN, BL ;
NASON, R .
HEALTH PHYSICS, 1986, 50 (04) :457-463
[4]   THEORY AND PRACTICE OF RADON MONITORING WITH CHARCOAL ADSORPTION [J].
COHEN, BL ;
COHEN, ES .
HEALTH PHYSICS, 1983, 45 (02) :501-508
[5]  
Evans R. D., 1955, ATOMIC NUCL, P711
[6]   AN IMPROVED PASSIVE ACTIVATED-C COLLECTOR FOR MEASURING ENVIRONMENTAL RN-222 IN INDOOR AIR [J].
GEORGE, AC ;
WEBER, T .
HEALTH PHYSICS, 1990, 58 (05) :583-589
[7]   PASSIVE, INTEGRATED MEASUREMENT OF INDOOR RADON USING ACTIVATED CARBON [J].
GEORGE, AC .
HEALTH PHYSICS, 1984, 46 (04) :867-872
[8]  
GRAY DJ, 1987, EPA520587005
[9]   THE ADSORPTION OF GASES ON PLANE SURFACES OF GLASS, MICA AND PLATINUM. [J].
Langmuir, Irving .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1918, 40 :1361-1403
[10]   PERFORMANCE OF A DIFFUSION BARRIER CHARCOAL ADSORPTION RN-222 MONITOR UNDER CONDITIONS OF VARYING HUMIDITY AND TEMPERATURE [J].
POJER, PM ;
PEGGIE, JR ;
OBRIEN, RS ;
SOLOMON, SB ;
WISE, KN .
HEALTH PHYSICS, 1990, 58 (01) :13-19