VALIDATION OF THE ANALYSIS OF CARBAMAZEPINE AND ITS 10,11-EPOXIDE METABOLITE BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY FROM PLASMA - COMPARISON WITH GAS-CHROMATOGRAPHY AND THE ENZYME-MULTIPLIED IMMUNOASSAY TECHNIQUE

被引:11
作者
MARTENS, J
BANDITT, P
机构
[1] Department of Clinical Pharmacology, University Hospital
来源
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS | 1993年 / 620卷 / 01期
关键词
D O I
10.1016/0378-4347(93)80067-E
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An improved procedure for the determination of carbamazepine (CBZ) and its main active metabolite carbamazepine-10,11-epoxide (CBZ-e) in serum is described. The validation of this procedure shows that the limits of detection are lower than 80 ng/ml for CBZ and 7 ng/ml for CBZ-e. The relative standard deviation does not exceed 4.7% for both compounds in an inter-day precision test. In the intra-day precision test the relative standard deviations are 1.9% for CBZ-e and 1.1% for CBZ. A comparison of the described procedure with gas chromatography and the enzyme-multiplied immunoassay technique shows good agreement, but gas chromatography seems to have a relative poor reliability.
引用
收藏
页码:169 / 173
页数:5
相关论文