3-DIMENSIONAL DISPLAY OF THE ORIFICE OF INTRACRANIAL ANEURYSMS - A NEW POTENTIAL APPLICATION FOR MAGNETIC-RESONANCE ANGIOGRAPHY

被引:15
作者
BONTOZOGLOU, N [1 ]
SPANOS, H [1 ]
LASJAUNIAS, P [1 ]
ZARIFIS, G [1 ]
机构
[1] CHU BICETRE,DEPT VASC NEURORADIOL,PARIS,FRANCE
关键词
INTRACRANIAL ANEURYSM; MAGNETIC RESONANCE ANGIOGRAPHY; INTERVENTIONAL NEURORADIOLOGY; MAGNETIC RESONANCE IMAGING; 3-DIMENSIONAL; MAGNETIC RESONANCE IMAGE PROCESSING;
D O I
10.1007/BF00612115
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Our aim was to demonstrate the orifice of intracranial aneurysms by magnetic resonance angiography (MRA). The aneurysmal orifice is that part of its lumen that communicates with the parent vessel. We studied 12 patients with 17 intracranial aneurysms using three-dimensional display (3DD) MRA; 15 of the aneurysms had previously been shown by digital subtraction angiography (DSA). The overall image quality of 3DD MRA was excellent in 10 patients. The orifice was clearly demonstrated in 13 aneurysms (76 %) providing unique information about its size, shape and orientation. The orifice of 2 aneurysms (12 %) was not demonstrated. Two aneurysms (12 %) were not detected on MRA. Although 3DD MRA has limitations, this study suggests that it can accurately define the orifice of aneurysms and could be used to provide information crucial for endovascular treatment.
引用
收藏
页码:346 / 349
页数:4
相关论文
共 15 条
  • [1] BALLOON OCCLUSION OF THE INTERNAL CAROTID-ARTERY IN 40 CASES OF GIANT INTRACAVERNOUS ANEURYSM - TECHNICAL ASPECTS, CEREBRAL MONITORING, AND RESULTS
    ANON, VV
    AYMARD, A
    GOBIN, YP
    CASASCO, A
    RUFFENACHT, D
    KHAYATA, MH
    ABIZANDA, E
    REDONDO, A
    MERLAND, JJ
    [J]. NEURORADIOLOGY, 1992, 34 (03) : 245 - 251
  • [2] AOKI S, 1992, AM J NEURORADIOL, V13, P1115
  • [3] AXEL L, 1989, RECENT ADV INTERVENT, P97
  • [4] CEREBRAL MR ANGIOGRAPHY WITH MULTIPLE OVERLAPPING THIN SLAB ACQUISITION .2. EARLY CLINICAL-EXPERIENCE
    BLATTER, DD
    PARKER, DL
    AHN, SS
    BAHR, AL
    ROBISON, RO
    SCHWARTZ, RB
    JOLESZ, FA
    BOYER, RS
    [J]. RADIOLOGY, 1992, 183 (02) : 379 - 389
  • [5] MR ANGIOGRAPHY
    EDELMAN, RR
    MATTLE, HP
    ATKINSON, DJ
    HOOGEWOUD, HM
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1990, 154 (05) : 937 - 946
  • [6] 3-DIMENSIONAL IMAGING
    FISHMAN, EK
    MAGID, D
    NEY, DR
    CHANEY, EL
    PIZER, SM
    ROSENMAN, JG
    LEVIN, DN
    VANNIER, MW
    KUHLMAN, JE
    ROBERTSON, DD
    [J]. RADIOLOGY, 1991, 181 (02) : 321 - 337
  • [7] MAGNETIC-RESONANCE ANGIOGRAPHY COMPARED TO INTRAARTERIAL DIGITAL SUBTRACTION ANGIOGRAPHY IN PATIENTS WITH SUBARACHNOID HEMORRHAGE
    GOULIAMOS, A
    GOTSIS, E
    VLAHOS, L
    SAMARA, C
    KAPSALAKI, E
    ROLOGIS, D
    KAPSALAKIS, Z
    PAPAVASILIOU, C
    [J]. NEURORADIOLOGY, 1992, 35 (01) : 46 - 49
  • [8] COMPARISON OF TIME-OF-FLIGHT AND PHASE-CONTRAST MR NEUROANGIOGRAPHIC TECHNIQUES
    HUSTON, J
    EHMAN, RL
    [J]. RADIOGRAPHICS, 1993, 13 (01) : 5 - 19
  • [9] NUMAGUCHI Y, 1992, NEURORADIOLOGY, V4, P252
  • [10] PERNICONE JR, 1990, AM J NEURORADIOL, V11, P457