IMPROVED METHOD FOR COMPUTING POTENTIAL DOUBLING TIME FROM FLOW CYTOMETRIC DATA

被引:93
作者
WHITE, RA [1 ]
TERRY, NHA [1 ]
MEISTRICH, ML [1 ]
CALKINS, DP [1 ]
机构
[1] UNIV TEXAS,MD ANDERSON HOSP & TUMOR INST,CTR CANC,DEPT EXPTL RADIOTHERAPY,HOUSTON,TX 77030
来源
CYTOMETRY | 1990年 / 11卷 / 02期
关键词
bromodeoxyuridine; labeling index; monoclonal antibodies; Relative movement;
D O I
10.1002/cyto.990110214
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Relative movement methods use the timed progression of the mean fluorescence of cells which have heen labeled with monoclonal antibodies against bromodeoxyuridine and displayed with bivariate flow cytometry according to DNA and label content to compute duration of DNA synthesis, Ts. The relative movement is the difference of the mean DNA fluorescence of the labeled undivided cells from the G1 channel relative to the difference between the G1 and G2M channels. In this communication, we show how to extend this method to compute the potential doubling time, Tpot, the time required for a population of cells to double, given quiescent cells but no cell loss. A quantity vis introduced that is a function of the fraction of labeled divided cells and the fraction of labeled undivided cells. We show that v is independent of time and is equal to In(2)T8/Tpot so that Tpot (equal to In(2)T8/v) can be directly found from the information available in computing the relative movement. The method is applied to Chinese hamster ovary cells to demonstrate its utility. Copyright © 1990 Wiley‐Liss, Inc.
引用
收藏
页码:314 / 317
页数:4
相关论文
共 9 条
  • [1] HUMAN-TUMOR CELL-KINETICS USING A MONOCLONAL-ANTIBODY AGAINST IODODEOXYURIDINE - INTRATUMOR SAMPLING VARIATIONS
    BEGG, AC
    MOONEN, L
    HOFLAND, I
    DESSING, M
    BARTELINK, H
    [J]. RADIOTHERAPY AND ONCOLOGY, 1988, 11 (04) : 337 - 347
  • [2] A METHOD TO MEASURE THE DURATION OF DNA-SYNTHESIS AND THE POTENTIAL DOUBLING TIME FROM A SINGLE SAMPLE
    BEGG, AC
    MCNALLY, NJ
    SHRIEVE, DC
    KARCHER, H
    [J]. CYTOMETRY, 1985, 6 (06): : 620 - 626
  • [3] FLOW CYTOMETRIC MEASUREMENT OF TOTAL DNA CONTENT AND INCORPORATED BROMODEOXYURIDINE
    DOLBEARE, F
    GRATZNER, H
    PALLAVICINI, MG
    GRAY, JW
    [J]. PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA-BIOLOGICAL SCIENCES, 1983, 80 (18): : 5573 - 5577
  • [4] AN ALGORITHM FOR LEAST-SQUARES ESTIMATION OF NONLINEAR PARAMETERS
    MARQUARDT, DW
    [J]. JOURNAL OF THE SOCIETY FOR INDUSTRIAL AND APPLIED MATHEMATICS, 1963, 11 (02): : 431 - 441
  • [5] RICCARDI A, 1988, CANCER RES, V48, P6238
  • [6] AN IMPROVED METHOD FOR THE IMMUNOCYTOCHEMICAL DETECTION OF BROMODEOXYURIDINE LABELED NUCLEI USING FLOW-CYTOMETRY
    SCHUTTE, B
    REYNDERS, MMJ
    VANASSCHE, CLMVJ
    HUPPERETS, PSGJ
    BOSMAN, FT
    BLIJHAM, GH
    [J]. CYTOMETRY, 1987, 8 (04): : 372 - 376
  • [7] WHITE RA, 1986, CYTOMETRY, V7, P486
  • [8] [No title captured]
  • [9] [No title captured]