AMPEROMETRIC ENZYME-MODIFIED ELECTRODES BASED ON TETRATHIAFULVALENE DERIVATIVES FOR THE DETERMINATION OF GLUCOSE

被引:18
作者
LEE, HS [1 ]
LIU, LF [1 ]
HALE, PD [1 ]
OKAMOTO, Y [1 ]
机构
[1] POLYTECH INST NEW YORK,DEPT CHEM,333 JAY ST,BROOKLYN,NY 11201
关键词
D O I
10.1002/hc.520030316
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A number of tetrathiafulvalene (TTF) derivatives have been synthesized and tested as electron transfer mediators in glucose oxidase-based amperometric biosensors. Using cyclic voltammetry and stationary potential experiments, it is shown that several of these derivatives can effectively mediate electron transfer from the reduced flavin adenine dinucleotide redox centers of glucose oxidase to a conventional carbon paste electrode. An insoluble polymeric electron relay system, based on the covalent attachment of TTF moieties to a highly flexible siloxane polymer, is also shown to facilitate a flow of electrons from the enzyme to the electrode. The resulting glucose biosensors function efficiently over a clinically relevant range of glucose concentrations.
引用
收藏
页码:303 / 310
页数:8
相关论文
共 32 条
[1]  
CARDOSI M F, 1987, Analytical Proceedings, V24, P143
[2]   FERROCENE-MEDIATED ENZYME ELECTRODE FOR AMPEROMETRIC DETERMINATION OF GLUCOSE [J].
CASS, AEG ;
DAVIS, G ;
FRANCIS, GD ;
HILL, HAO ;
ASTON, WJ ;
HIGGINS, IJ ;
PLOTKIN, EV ;
SCOTT, LDL ;
TURNER, APF .
ANALYTICAL CHEMISTRY, 1984, 56 (04) :667-671
[3]  
Clark L. C., 1987, BIOSENSORS FUNDAMENT
[4]   ELECTRODE SYSTEMS FOR CONTINUOUS MONITORING IN CARDIOVASCULAR SURGERY [J].
CLARK, LC ;
LYONS, C .
ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1962, 102 (01) :29-&
[5]   IMMOBILIZATION OF GLUCOSE-OXIDASE IN FERROCENE-MODIFIED PYRROLE POLYMERS [J].
FOULDS, NC ;
LOWE, CR .
ANALYTICAL CHEMISTRY, 1988, 60 (22) :2473-2478
[6]   A GLUCOSE ELECTRODE BASED ON CARBON PASTE CHEMICALLY MODIFIED WITH A FERROCENE-CONTAINING SILOXANE POLYMER AND GLUCOSE-OXIDASE, COATED WITH A POLY(ESTER-SULFONIC ACID) CATION-EXCHANGER [J].
GORTON, L ;
KARAN, HI ;
HALE, PD ;
INAGAKI, T ;
OKAMOTO, Y ;
SKOTHEIM, TA .
ANALYTICA CHIMICA ACTA, 1990, 228 (01) :23-30
[7]  
GREEN DC, 1982, Patent No. 4312992
[8]   CROSS-LINKED REDOX GELS CONTAINING GLUCOSE-OXIDASE FOR AMPEROMETRIC BIOSENSOR APPLICATIONS [J].
GREGG, BA ;
HELLER, A .
ANALYTICAL CHEMISTRY, 1990, 62 (03) :258-263
[9]   COMPARATIVE-STUDY OF 1ST-GENERATION, 2ND-GENERATION AND 3RD-GENERATION AMPEROMETRIC GLUCOSE ENZYME ELECTRODES IN CONTINUOUS-FLOW ANALYSIS OF UNDILUTED WHOLE-BLOOD [J].
GUNASINGHAM, H ;
TAN, CH ;
AW, TC .
ANALYTICA CHIMICA ACTA, 1990, 234 (02) :321-330
[10]   CARBON PASTE-TETRATHIAFULVALENE AMPEROMETRIC ENZYME ELECTRODE FOR THE DETERMINATION OF GLUCOSE IN FLOWING SYSTEMS [J].
GUNASINGHAM, H ;
TAN, CH .
ANALYST, 1990, 115 (01) :35-39