QUANTITATIVE STUDY OF SELF-ABSORPTION IN NEAR-INFRARED FOURIER-TRANSFORM RAMAN-SPECTROSCOPY

被引:13
作者
EVERALL, N
机构
[1] ICI plc, Wilton Research Centre, Cleveland, TS90 8JE, P.O. Box 90, Wilton, Middlesbrough
关键词
D O I
10.1002/jrs.1250251007
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
Self-absorption occurs in near-infrared Fourier transform (NIR-FT) Raman spectroscopy when the absolute frequency of a Raman band coincides with an NIR absorption band of the scattering material. This is manifested by selective attention of specific Raman bands, the degree of which depends on the sample pathlength, concentration and position in the laser beam. These factors can introduce serious errors in quantitative FT Raman applications unless care is taken. This paper describes a simple analysis which allows quantitative predictions of the effects of varying sample concentration and collection optics geometry. The predictions for concentration variation have been validated by experiment. A consideration of the experimental design required to minimize self-adsorption indicates that this will also reduce instrument sensitivity and ease of alignment; therefore, there is a trade-off between optimizing instruments for quantitative applications whilst maintaining sensitivity and ease of use.
引用
收藏
页码:813 / 819
页数:7
相关论文
共 13 条
[1]   A COMPARISON OF FOURIER-TRANSFORM INFRARED AND NEAR-INFRARED FOURIER-TRANSFORM RAMAN-SPECTROSCOPY FOR QUANTITATIVE MEASUREMENTS - AN APPLICATION IN POLYMORPHISM [J].
DEELEY, CM ;
SPRAGG, RA ;
THRELFALL, TL .
SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 1991, 47 (9-10) :1217-1223
[2]   VARIATIONS IN RELATIVE BAND INTENSITIES IN FOURIER-TRANSFORM RAMAN-SPECTRA AS A FUNCTION OF SAMPLE ALIGNMENT - PRELIMINARY-OBSERVATIONS [J].
EVERALL, N ;
LUMSDON, J .
VIBRATIONAL SPECTROSCOPY, 1991, 2 (04) :257-261
[3]   MEASUREMENT OF POLY(ARYL ETHER ETHER KETONE) CRYSTALLINITY IN ISOTROPIC AND UNIAXIAL SAMPLES USING FOURIER-TRANSFORM RAMAN-SPECTROSCOPY - A COMPARISON OF UNIVARIATE AND PARTIAL LEAST-SQUARES CALIBRATIONS [J].
EVERALL, NJ ;
CHALMERS, JM ;
FERWERDA, R ;
VANDERMAAS, JH ;
HENDRA, PJ .
JOURNAL OF RAMAN SPECTROSCOPY, 1994, 25 (01) :43-51
[4]  
EVERALL NJ, 1992, SPECTROSC EUR, V4, P10
[5]  
GILSON TR, 1970, LASER RAMAN SPECTROS, pCH3
[6]  
Hendra P. J., 1991, FT RAMAN SPECTROSCOP
[7]   A STANDARDIZED INTENSITY SCALE FOR FOURIER-TRANSFORM RAMAN-SPECTRA OF LIQUIDS [J].
PETTY, CJ ;
HENDRA, PJ ;
JAWHARI, T .
SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 1991, 47 (9-10) :1189-1199
[8]   SELF-ABSORPTION IN NEAR-INFRARED FOURIER-TRANSFORM RAMAN-SPECTROMETRY [J].
PETTY, CJ .
VIBRATIONAL SPECTROSCOPY, 1991, 2 (04) :263-268
[9]   NEAR-INFRARED FOURIER-TRANSFORM RAMAN-SPECTROSCOPY - FACING ABSORPTION AND BACKGROUND [J].
SCHRADER, B ;
HOFFMANN, A ;
KELLER, S .
SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 1991, 47 (9-10) :1135-1148
[10]  
TURNER P, COMMUNICATION