CONTINUOUS RECORDING OF HYDROSTATIC PRESSURE IN RENAL TUBULES AND BLOOD CAPILLARIES BY USE OF A NEW PRESSURE TRANSDUCER

被引:18
作者
WUNDERLICH, P
SCHNERMANN, J
机构
[1] Physiologisches Institut der Universität, München 15, 8000
来源
PFLUGERS ARCHIV-EUROPEAN JOURNAL OF PHYSIOLOGY | 1969年 / 313卷 / 01期
关键词
Continuous Recording; Hydrostatic Pressure; Pressure Transducer;
D O I
10.1007/BF00586332
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Using a new ultra miniature pressure sensor hydrostatic pressure in renal tubules and renal blood capillaries was continuously recorded. The transducer was mounted in a special plexiglas device which was fixed on a micromanipulator. With a glass capillary attached to one end of the plexiglas block tubules and capillaries were punctured using conventional micropuncture techniques. The volume displacement of this transducer is about 1 nl/10 mm Hg. The recorded signal was found to be linear up to 300 mm Hg. The frequency of the system was highly dependent upon the capillary tip diameter. Examples of recorded pressures in renal tubules and blood capillaries are given. © 1969 Springer-Verlag.
引用
收藏
页码:89 / +
页数:1
相关论文
共 1 条
[1]   The capillary pressure in frog mesentery as determined by micro-injection methods [J].
Landis, EM .