DETERMINATION OF HYDROGEN-PEROXIDE BY FLOW-INJECTION ANALYSIS WITH ARYL OXALATE-SULFORHODAMINE-101 CHEMILUMINESCENCE

被引:20
作者
KATAYAMA, M
TAKEUCHI, H
TANIGUCHI, H
机构
[1] Meiji College of Pharmacy, Setagaya-ku, Tokyo, 154
关键词
CHEMILUMINESCENCE; SULFORHODAMINE-101; HYDROGEN PEROXIDE; ARYL OXALATE; FLOW INJECTION ANALYSIS; TDPO;
D O I
10.1080/00032719108054370
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A flow injection analysis (FIA) method for the determination of hydrogen peroxide by aryl oxalate chemiluminescence detection was studied. The analyte was detected by using sulforhodamine 101 as a new fluorophore and bis[4-nitro-2-(3,6,9-trioxadecyloxycarbonyl)phenyl]oxalate (TDPO) in imidazole buffer (pH 7.0)-acetonitrile. The detection limit was 3.0 x 10(-9) M. The relative standard deviation (n = 6) for 1.0 x 10(-6) M hydrogen peroxide was 2.8 %. This FIA method was shown to be 20 to 2500 times more sensitive than the previous FIA method with aryl oxalate chemiluminescence.
引用
收藏
页码:1005 / 1015
页数:11
相关论文
共 22 条
[1]   NATIVE PEROXYOXALATE CHEMILUMINESCENCE FROM THE REACTION OF BIS(2,4-DINITROPHENYL) OXALATE AND HYDROGEN-PEROXIDE PERTURBED BY NONFLUOROPHORES [J].
CAPOMACCHIA, AC ;
JENNINGS, RN ;
HEMINGWAY, SM ;
DSOUZA, P ;
PRAPAITRAKUL, W ;
GINGLE, A .
ANALYTICA CHIMICA ACTA, 1987, 196 :305-310
[2]   IMMOBILIZED FLUOROPHORES IN DYNAMIC CHEMI-LUMINESCENCE DETECTION OF HYDROGEN-PEROXIDE [J].
GUBITZ, G ;
VANZOONEN, P ;
GOOIJER, C ;
VELTHORST, NH ;
FREI, RW .
ANALYTICAL CHEMISTRY, 1985, 57 (11) :2071-2074
[3]   EVALUATION OF FLUORESCENT COMPOUNDS FOR PEROXYOXALATE CHEMILUMINESCENCE DETECTION [J].
HONDA, K ;
MIYAGUCHI, K ;
IMAI, K .
ANALYTICA CHIMICA ACTA, 1985, 177 :111-120
[4]   IMMOBILIZED LUMINOL CHEMI-LUMINESCENCE REAGENT SYSTEM FOR HYDROGEN-PEROXIDE DETERMINATIONS IN FLOWING STREAMS [J].
HOOL, K ;
NIEMAN, TA .
ANALYTICAL CHEMISTRY, 1988, 60 (09) :834-837
[5]   NOVEL ARYL OXALATE ESTERS FOR PEROXYOXALATE CHEMILUMINESCENCE REACTIONS [J].
IMAI, K ;
NAWA, H ;
TANAKA, M ;
OGATA, H .
ANALYST, 1986, 111 (02) :209-211
[6]   APPLICATION OF BIS[4-NITRO-2-(3,6,9-TRIOXADECYLOXYCARBONYL)-PHENYL]OXALATE TO POSTCOLUMN CHEMILUMINESCENCE DETECTION IN HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
IMAI, K ;
MATSUNAGA, Y ;
TSUKAMOTO, Y ;
NISHITANI, A .
JOURNAL OF CHROMATOGRAPHY, 1987, 400 :169-176
[7]   DETERMINATION OF CATECHOLAMINES WITH LUCIGENIN CHEMI-LUMINESCENCE [J].
KAMIDATE, T ;
YOSHIDA, K ;
SEGAWA, T ;
WATANABE, H .
ANALYTICAL SCIENCES, 1989, 5 (03) :359-360
[8]   DETERMINATION OF FLUORESCENT COMPOUNDS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH CHEMI-LUMINESCENCE DETECTION [J].
KOBAYASHI, S ;
IMAI, K .
ANALYTICAL CHEMISTRY, 1980, 52 (03) :424-427
[9]   DETERMINATION OF TRACE LEVELS OF STEROIDS IN BLOOD-PLASMA BY LIQUID-CHROMATOGRAPHY WITH PEROXYOXALATE CHEMI-LUMINESCENCE DETECTION [J].
KOZIOL, T ;
GRAYESKI, ML ;
WEINBERGER, R .
JOURNAL OF CHROMATOGRAPHY, 1984, 317 (DEC) :355-366
[10]   RHODAMINE LABELING REAGENT FOR THE DETERMINATION OF CHLOROPHENOLS BY LIQUID-CHROMATOGRAPHY WITH PEROXYOXALATE CHEMI-LUMINESCENCE DETECTION [J].
KWAKMAN, PJM ;
MOL, JGJ ;
KAMMINGA, DA ;
FREI, RW ;
BRINKMAN, UAT ;
DEJONG, GJ .
JOURNAL OF CHROMATOGRAPHY, 1988, 459 :139-149