COMPLIANCE OF THE MAIN PULMONARY-ARTERY DURING THE VENTILATORY CYCLE

被引:7
作者
GRANT, BJB
LIEBER, BB
机构
[1] SUNY BUFFALO,DEPT MED,BUFFALO,NY 14215
[2] SUNY BUFFALO,DEPT MECH & AEROSP ENGN,BUFFALO,NY 14215
关键词
PULMONARY ARTERIAL COMPLIANCE; POSITIVE END-EXPIRATORY PRESSURE; RESPIRATORY CYCLE; TIME-VARYING COMPLIANCE; DOGS;
D O I
10.1152/jappl.1992.72.2.535
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Transmural pulmonary arterial pressure (Ppa), diameter (D), and length (L) of a segment of the main pulmonary artery (MPA) were measured simultaneously in anesthetized open-chest dogs. The instantaneous volume was calculated from D and L. Pulmonary arterial elasticity for diameter (Ep(D)) was calculated as the ratio of the amplitude of Ppa to D oscillations normalized by the mean D. Similar indexes were calculated for the L (Ep(L)) and V (Ep(v)). Compliance per unit length was calculated from the dimensions and elasticity of the MPA. Under control conditions with 5 cmH2O positive end-expiratory pressure, Ep(D), Ep(L), and Ep(v) at cardiac frequency were 175 +/- 27, 147 +/- 27, and 55 +/- 7 cmH2O, respectively. Ep(D) increased with positive end-expiratory pressure, but Ep(L) decreased and Ep(v) was unaffected. Ep(D), Ep(L), Ep(v), and compliance per unit length were not significantly different between the start of inspiration and the start of expiration. In addition, there were no significant phase differences between the oscillations of Ppa and V at respiratory frequency. We conclude that the previously reported time variation of pulmonary arterial compliance during the ventilatory cycle is not due to time-varying properties of the MPA.
引用
收藏
页码:535 / 542
页数:8
相关论文
共 13 条
[1]  
Feigenbaum H., 1981, ECHOCARDIOGR-J CARD, P188
[2]   REGIONAL VOLUME DISTENSIBILITY OF CANINE THORACIC AORTA DURING MODERATE TREADMILL EXERCISE [J].
GENTILE, BJ ;
CHUONG, CJC ;
ORDWAY, GA .
CIRCULATION RESEARCH, 1988, 63 (06) :1012-1019
[3]  
Glantz SA, 1990, PRIMER APPL REGRESSI, P381
[4]   EFFECT OF CARDIAC-OUTPUT ON PULMONARY HEMODYNAMICS [J].
GRANT, BJB ;
CANTY, JM .
RESPIRATION PHYSIOLOGY, 1989, 76 (03) :303-317
[5]   TIME-VARYING PULMONARY ARTERIAL COMPLIANCE [J].
GRANT, BJB ;
FITZPATRICK, JM ;
LIEBER, BB .
JOURNAL OF APPLIED PHYSIOLOGY, 1991, 70 (02) :575-583
[6]   TWO-DIMENSIONAL INVIVO PRESSURE DIAMETER RELATIONSHIPS IN THE CANINE MAIN PULMONARY-ARTERY [J].
JOHNSON, TA ;
HENRY, GW ;
LUCAS, CL ;
KEAGY, BA ;
LORES, ME ;
HSIAO, HS ;
FERREIRO, JI ;
WILCOX, BR .
CARDIOVASCULAR RESEARCH, 1985, 19 (07) :442-448
[7]  
LEE CL, 1990, 1990 ADV BIOENGINEER, P39
[8]  
MILNOR WR, 1989, HEMODYNAMICS, P11
[9]   IN SITU PRESSURE-RADIUS-LENGTH MEASUREMENTS IN ASCENDING AORTA OF ANESTHETIZED DOGS [J].
PATEL, DJ ;
FRY, DL .
JOURNAL OF APPLIED PHYSIOLOGY, 1964, 19 (03) :413-+
[10]   MECHANICAL PROPERTIES AND DIMENSIONS OF THE MAJOR PULMONARY ARTERIES [J].
PATEL, DJ ;
SCHILDER, DP ;
MALLOS, AJ .
JOURNAL OF APPLIED PHYSIOLOGY, 1960, 15 (01) :92-96