EFFECT OF TENDON ORIENTATION ON MR IMAGING SIGNAL INTENSITY - A MANIFESTATION OF THE MAGIC ANGLE PHENOMENON

被引:221
作者
ERICKSON, SJ
COX, IH
HYDE, JS
CARRERA, GF
STRANDT, JA
ESTKOWSKI, LD
机构
[1] Department of Radiology, Medical College of Wisconsin, Milwaukee, WI 53226
关键词
MAGNETIC RESONANCE (MR); ARTIFACT; EXPERIMENTAL; TISSUE CHARACTERIZATION; TENDONS; MR STUDIES;
D O I
10.1148/radiology.181.2.1924777
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
To determine whether orientation in the static field may be responsible for the frequent occurrence of increased signal intensity within normal tendons at magnetic resonance (MR) imaging, seven healthy volunteers were imaged by means of a 1.5-T unit and standard clinical pulse sequences. The wrist, ankle, and shoulder regions were evaluated with local coils. Imaging was performed with tendon orientations ranging from 0-degrees to 90-degrees in relation to the constant magnetic induction field (B0). Markedly increased intratendinous signal intensity was observed at the "magic angle" of 55-degrees, intermediate signal intensity was observed at 45-degrees and 65-degrees, and no signal intensity was observed at 0-degrees and 90-degrees. Signal intensity was evident only when a short echo time was used. The authors believe that tendon orientation greatly affects tendon signal intensity in vivo. Increased signal intensity due to the magic angle effect may be misdiagnosed as tendinous degeneration, tendinitis, or frank tear.
引用
收藏
页码:389 / 392
页数:4
相关论文
共 11 条
[1]
TENDONS - HIGH-FIELD-STRENGTH, SURFACE COIL MR IMAGING [J].
BELTRAN, J ;
NOTO, AM ;
HERMAN, LJ ;
LUBBERS, LM .
RADIOLOGY, 1987, 162 (03) :735-740
[2]
BERENDSEN H. J. C, 1965, ANN N Y ACAD SCI, V125, P365, DOI 10.1111/j.1749-6632.1965.tb45403.x
[3]
NUCLEAR MAGNETIC RESONANCE STUDY OF COLLAGEN HYDRATION [J].
BERENDSEN, HJC .
JOURNAL OF CHEMICAL PHYSICS, 1962, 36 (12) :3297-&
[4]
ORIENTATION OF TENDONS IN THE MAGNETIC-FIELD AND ITS EFFECT ON T2 RELAXATION-TIMES [J].
FULLERTON, GD ;
CAMERON, IL ;
ORD, VA .
RADIOLOGY, 1985, 155 (02) :433-435
[5]
Lehninger A.L., 1975, BIOCHEMISTRY-US
[6]
McGilvery R, 1979, BIOCH FUNCTIONAL APP
[7]
STRUCTURE AND DYNAMICS OF WATER IN TENDON FROM NMR RELAXATION MEASUREMENTS [J].
PETO, S ;
GILLIS, P ;
HENRI, VP .
BIOPHYSICAL JOURNAL, 1990, 57 (01) :71-84
[8]
ACHILLES-TENDON - MR IMAGING AT 1.5-T [J].
QUINN, SF ;
MURRAY, WT ;
CLARK, RA ;
COCHRAN, CF .
RADIOLOGY, 1987, 164 (03) :767-770
[9]
RUPTURE OF POSTERIOR TIBIAL TENDON - CT AND MR IMAGING WITH SURGICAL CORRELATION [J].
ROSENBERG, ZS ;
CHEUNG, Y ;
JAHSS, MH ;
NOTO, AM ;
NORMAN, A ;
LEEDS, NE .
RADIOLOGY, 1988, 169 (01) :229-235
[10]
WARREN WS, 1989, ADV MAGNETIC RESONAN