STUDY OF TREATMENT VARIATION IN THE RADIOTHERAPY OF HEAD AND NECK TUMORS USING A FIBEROPTIC ONLINE RADIOTHERAPY IMAGING-SYSTEM

被引:33
作者
HALVERSON, KJ
LEUNG, TC
PELLET, JB
GERBER, RL
WEINHOUS, MS
WONG, JW
机构
[1] WASHINGTON UNIV,SCH MED,EDWARD MALLINCKRODT INST RADIOL,DIV RADIAT ONCOL,ST LOUIS,MO 63110
[2] FIBER IMAGING INC,ST LOUIS,MO 63103
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 1991年 / 21卷 / 05期
关键词
TREATMENT VERIFICATION; ONLINE RADIOTHERAPY IMAGING; DAILY TREATMENT VARIATION;
D O I
10.1016/0360-3016(91)90294-E
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
On-line radiotherapy imaging systems allow convenient daily acquisition of portal images for treatment verification. The information can also be used to study treatment variability. Using a prototype fiber-optic imaging system, we have measured the treatment variation of 17 head and neck patients. Daily digital portal images were acquired for the on-cord left and right lateral fields. Treatment variations were quantified using the Cumulative Verification Image Analysis (CVIA) method developed at our institute. In the CVIA method, daily portal images were aligned according to three anatomical points predefined on a digitized simulation, or prescription, image. After each image alignment, the block position was cumulated in a bit-map and superimposed on the prescription image to give a cumulative verification summary image. Iso-frequency distributions, or contours, of the block overlap were calculated and examined with respect to the prescription treatment area. The range of the treatment variation was large for the 17 patients. On average, separation of the 0% to 100% block overlap contours was about 10 mm, and the 20% to 80%, 5 mm. The block overlap contours were also used to calculate the frequency with which the prescription area as defined on the simulation film had been treated. The fraction of the prescription area treated depended on the accuracy of the treatment setup and patient repositioning, as expected. At best, approximately 95% of the prescribed area was irradiated 100% of the time during the entire course of radiotherapy. At worst, approximately 70% of the prescribed area was irradiated 100% of the time. These results demonstrate that despite immobilization, large setup variation can still occur. Presenting treatment variation data as population averages does not reflect on the large variation that may be observed in the individual patient.
引用
收藏
页码:1327 / 1336
页数:10
相关论文
共 16 条
  • [1] WEEKLY LOCALIZATION FILMS AND DETECTION OF FIELD PLACEMENT ERRORS
    BYHARDT, RW
    COX, JD
    HORNBURG, A
    LIERMANN, G
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1978, 4 (9-10): : 881 - 887
  • [2] IMMOBILIZATION ERROR - SOME THEORETICAL CONSIDERATIONS
    GOITEIN, M
    BUSSE, J
    [J]. RADIOLOGY, 1975, 117 (02) : 407 - 412
  • [3] A METHOD TO ANALYZE 2-DIMENSIONAL DAILY RADIOTHERAPY PORTAL IMAGES FROM AN ONLINE FIBEROPTIC IMAGING-SYSTEM
    GRAHAM, ML
    CHENG, AY
    GEER, LY
    BINNS, WR
    VANNIER, MW
    WONG, JW
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1991, 20 (03): : 613 - 619
  • [4] ACCURACY IN RADIATION-FIELD ALIGNMENT IN HEAD AND NECK-CANCER - A PROSPECTIVE-STUDY
    HUIZENGA, H
    LEVENDAG, PC
    DEPORRE, PMZR
    VISSER, AG
    [J]. RADIOTHERAPY AND ONCOLOGY, 1988, 11 (02) : 181 - 187
  • [5] JACOBSEN A, 1987, RADIOTHER ONCOL, V8, P145
  • [6] KINZIE JJ, 1983, CANCER, V52, P2223, DOI 10.1002/1097-0142(19831215)52:12<2223::AID-CNCR2820521209>3.0.CO
  • [7] 2-D
  • [8] EFFECT OF IMMOBILIZATION ON LOCALIZATION ERROR IN RADIOTHERAPY OF HEAD AND NECK CANCER
    MARKS, JE
    HAUS, AG
    [J]. CLINICAL RADIOLOGY, 1976, 27 (02) : 175 - 177
  • [9] MARKS JE, 1976, CANCER, V37, P2755, DOI 10.1002/1097-0142(197606)37:6<2755::AID-CNCR2820370628>3.0.CO
  • [10] 2-J