ARTERIAL AND VENOUS-BLOOD FLOW - NONINVASIVE QUANTITATION WITH MR IMAGING

被引:153
作者
PELC, LR [1 ]
PELC, NJ [1 ]
RAYHILL, SC [1 ]
CASTRO, LJ [1 ]
GLOVER, GH [1 ]
HERFKENS, RJ [1 ]
MILLER, DC [1 ]
JEFFREY, RB [1 ]
机构
[1] STANFORD UNIV,MED CTR,SCH MED,DEPT CARDIOTHORAC SURG,STANFORD,CA 94305
关键词
BLOOD; FLOW DYNAMICS; MR; US; MAGNETIC RESONANCE (MR); PHASE IMAGING;
D O I
10.1148/radiology.185.3.1438767
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Quantitative measurements of arterial and venous blood flow were obtained with phase-contrast cine magnetic resonance (MR) imaging and compared with such measurements obtained by means of implanted ultrasound (US) blood flow probes in anesthetized dogs. The US flowmeter was enabled during a portion of each MR imaging sequence to allow virtually simultaneous data acquisition with the two techniques. MR imaging data were gated by means of electrocardiography and divided into 16 phases per cardiac cycle. The rates of portal venous blood flow measured with MR imaging and averaged across the cardiac cycle (710 mL/min +/- 230 [standard deviation]) correlated well with those measured with the flowmeter and averaged in like fashion (751 mL/min +/- 238) (r = .995, slope = 1.053). The correspondence in arterial blood flow was almost as good. No statistically significant difference existed between the paired measurements of blood flow obtained with MR imaging and the implanted probe. It is concluded that, as a noninvasive means of accurate quantification of blood flow, phase-contrast MR imaging may be especially useful in deep blood vessels in humans.
引用
收藏
页码:809 / 812
页数:4
相关论文
共 12 条
  • [1] ARMITAGE P, 1971, STATISTICAL METHODS, P186
  • [2] Burton RG, 1984, MED ELECTRONICS, V15, P68
  • [3] RIGHT AND LEFT LUNG PERFUSION - INVITRO AND INVIVO VALIDATION WITH OBLIQUE-ANGLE, VELOCITY-ENCODED CINE MR IMAGING
    CAPUTO, GR
    KONDO, C
    MASUI, T
    GERACI, SJ
    FOSTER, E
    OSULLIVAN, MM
    HIGGINS, CB
    [J]. RADIOLOGY, 1991, 180 (03) : 693 - 698
  • [4] QUANTIFICATION OF BLOOD-FLOW WITH DYNAMIC MR IMAGING AND PRESATURATION BOLUS TRACKING
    EDELMAN, RR
    MATTLE, HP
    KLEEFIELD, J
    SILVER, MS
    [J]. RADIOLOGY, 1989, 171 (02) : 551 - 556
  • [5] INVIVO VALIDATION OF MR VELOCITY IMAGING
    FIRMIN, DN
    NAYLER, GL
    KLIPSTEIN, RH
    UNDERWOOD, SR
    REES, RSO
    LONGMORE, DB
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1987, 11 (05) : 751 - 756
  • [6] HARTMAN J, 1985, PHARMACOLOGIST, V27, P217
  • [7] RIGHT AND LEFT-VENTRICULAR STROKE VOLUME MEASUREMENTS WITH VELOCITY-ENCODED CINE MR IMAGING - INVITRO AND INVIVO VALIDATION
    KONDO, C
    CAPUTO, GR
    SEMELKA, R
    FOSTER, E
    SHIMAKAWA, A
    HIGGINS, CB
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1991, 157 (01) : 9 - 16
  • [8] BLOOD-FLOW IMAGING BY CINE MAGNETIC-RESONANCE
    NAYLER, GL
    FIRMIN, DN
    LONGMORE, DB
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1986, 10 (05) : 715 - 722
  • [9] PELC N J, 1991, Magnetic Resonance Quarterly, V7, P229
  • [10] PELC NJ, 1991, RADIOLOGY, V181, P189