SERIAL ANGIOGRAPHIC FOLLOW-UP AFTER PALMAZ-SCHATZ STENT IMPLANTATION - COMPARISON WITH CONVENTIONAL BALLOON ANGIOPLASTY

被引:141
作者
KIMURA, T
NOSAKA, H
YOKOI, H
IWABUCHI, M
NOBUYOSHI, M
机构
[1] Department of Cardiology, Kokura Memorial Hospital, Kitakyushu
关键词
D O I
10.1016/0735-1097(93)90368-B
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives. Serial angiographic follow-up study was designed to evaluate the temporal mode of lumen diameter changes after Palmaz-Schatz stent implantation, and the results were compared with those from a cohort of patients undergoing balloon angioplasty. Background. Restenosis remains a major limitation of balloon angioplasty. The Palmaz-Schatz balloon expandable coronary stent is now under clinical investigation to evaluate its efficacy in preventing restenosis. Methods. Serial angiographic follow-up study was performed the day after stent implantation and at 1, 3 and 6 months after the procedure. The stent group consisted of % patients who had 97 lesions with a single stent. A cohort of 179 patients with 192 lesions were selected as the balloon group by the criteria of final balloon size greater-than-or-equal-to 3 mm and lesion length <20 mm. Results. A significantly larger lumen diameter was obtained immediately after stent implantation (2.9 +/- 0.4 mm [mean +/- SD] in the stent group vs. 2.1 +/- 0.5 mm in the balloon group, p < 0.001). At 3 to 6 months of follow-up, a significantly larger lumen diameter was maintained in the stent group (2.2 +/- 0.6 vs. 1.5 +/- 0.7 mm, p < 0.001). The late restenosis rate according to a binary definition was significantly lower in the stent group (13% vs. 39%, p < 0.001). Stenosis exacerbation, frequently observed within 24 h after balloon angioplasty, was not found after stenting. Between the next day and 1 month, regression was dominant in the balloon group, whereas progression of stenosis was observed in the stent group. The greatest tendency to restenosis was observed in both groups between 1 and 3 months after the procedure. Between 3 and 6 months, significantly greater diameter loss was found in the stent group. Conclusions. The Palmaz-Schatz stent was effective in reducing the restenosis rate in this highly selected cohort of patients. Reduction in restenosis rate was dependent on a larger lumen obtained immediately. Late loss of diameter was significantly greater after stenting. The restenosis rate after stenting should be evaluated by follow-up angiography at 6 months rather than at 3 months, which is adequate after conventional balloon angioplasty.
引用
收藏
页码:1557 / 1563
页数:7
相关论文
共 22 条
  • [1] INTIMAL PROLIFERATION OF SMOOTH-MUSCLE CELLS AS AN EXPLANATION FOR RECURRENT CORONARY-ARTERY STENOSIS AFTER PERCUTANEOUS TRANS-LUMINAL CORONARY ANGIOPLASTY
    AUSTIN, GE
    RATLIFF, NB
    HOLLMAN, J
    TABEI, S
    PHILLIPS, DF
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1985, 6 (02) : 369 - 375
  • [2] RESTENOSIS AFTER CORONARY ANGIOPLASTY - THE PARADOX OF INCREASED LUMEN DIAMETER AND RESTENOSIS
    BEATT, KJ
    SERRUYS, PW
    LUIJTEN, HE
    RENSING, BJ
    SURYAPRANATA, H
    DEFEYTER, P
    VANDENBRAND, M
    LAARMAN, GJ
    ROELANDT, J
    VANES, GA
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1992, 19 (02) : 258 - 266
  • [3] BONNER RF, 1991, CIRCULATION S2, V84, P197
  • [4] ANGIOGRAPHIC AND CLINICAL OUTCOME OF INTRACORONARY STENTING - IMMEDIATE AND LONG-TERM RESULTS FROM A LARGE SINGLE-CENTER EXPERIENCE
    CARROZZA, JP
    KUNTZ, RE
    LEVINE, MJ
    POMERANTZ, RM
    FISHMAN, RF
    MANSOUR, M
    GIBSON, CM
    SENERCHIA, CC
    DIVER, DJ
    SAFIAN, RD
    BAIM, DS
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1992, 20 (02) : 328 - 337
  • [5] TRANSLUMINAL TREATMENT OF ARTERIOSCLEROTIC OBSTRUCTION - DESCRIPTION OF NEW TECHNIC + PRELIMINARY REPORT OF ITS APPLICATION
    DOTTER, CT
    JUDKINS, MP
    [J]. CIRCULATION, 1964, 30 (05) : 654 - &
  • [6] EFFECT OF INTRACORONARY STENTING ON INTIMAL DISSECTION AFTER BALLOON ANGIOPLASTY - RESULTS OF QUANTITATIVE AND QUALITATIVE CORONARY ANALYSIS
    FISCHMAN, DL
    SAVAGE, MP
    LEON, MB
    SCHATZ, RA
    ELLIS, SG
    CLEMAN, MW
    TEIRSTEIN, P
    WALKER, CM
    BAILEY, S
    HIRSHFELD, JW
    GOLDBERG, S
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1991, 18 (06) : 1445 - 1451
  • [7] HAUDE M, 1991, BRIT HEART J, V66, P337
  • [8] RESTENOSIS AFTER CORONARY ANGIOPLASTY - A MULTIVARIATE STATISTICAL-MODEL TO RELATE LESION AND PROCEDURE VARIABLES TO RESTENOSIS
    HIRSHFELD, JW
    SCHWARTZ, JS
    JUGO, R
    MACDONALD, RG
    GOLDBERG, S
    SAVAGE, MP
    BASS, TA
    VETROVEC, G
    COWLEY, M
    TAUSSIG, AS
    WHITWORTH, HB
    MARGOLIS, JR
    HILL, JA
    PEPINE, CJ
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1991, 18 (03) : 647 - 656
  • [9] NOVEL-APPROACH TO THE ANALYSIS OF RESTENOSIS AFTER THE USE OF 3 NEW CORONARY DEVICES
    KUNTZ, RE
    SAFIAN, RD
    LEVINE, MJ
    REIS, GJ
    DIVER, DJ
    BAIM, DS
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1992, 19 (07) : 1493 - 1499
  • [10] GENERALIZED-MODEL OF RESTENOSIS AFTER CONVENTIONAL BALLOON ANGIOPLASTY, STENTING AND DIRECTIONAL ATHERECTOMY
    KUNTZ, RE
    GIBSON, CM
    NOBUYOSHI, M
    BAIM, DS
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 21 (01) : 15 - 25