EFFECT OF COLUMN INCLINATION ON THE PERFORMANCE OF 3-PHASE FLUIDIZED-BEDS

被引:17
作者
DELPOZO, M [1 ]
BRIENS, CL [1 ]
WILD, G [1 ]
机构
[1] CNRS,SCI GENIE CHIM LAB,F-54001 NANCY,FRANCE
关键词
D O I
10.1002/aic.690380808
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Inclining a fluidized bed column by as little as 1.5 degrees greatly affects the bed characteristics. The bed contracts, the particle-liquid mass-transfer and heat-transfer coefficients increase by up to 30 %, and the gas-liquid mass-transfer coefficient can either be increased by up to 15 % or decreased by up to 20 %.
引用
收藏
页码:1206 / 1212
页数:7
相关论文
共 13 条
[1]   GAS HOLDUP IN 3-PHASE IMMOBILIZED-CELL BIOREACTORS [J].
BAJPAI, R ;
THOMPSON, JE ;
DAVISON, BH .
APPLIED BIOCHEMISTRY AND BIOTECHNOLOGY, 1990, 24-5 :485-496
[2]  
BRIENS CL, 1992, IN PRESS CHEM ENG SC
[3]  
DELPOZO M, 1991, UNPUB CHEM ENG J
[4]  
DELPOZO M, 1991, JUN WORLD C CHEM ENG
[5]   SIMULTANEOUS MEASUREMENT OF INTERFACIAL AREA AND MASS-TRANSFER COEFFICIENT IN 3-PHASE FLUIDIZED-BEDS [J].
DHANUKA, VR ;
STEPANEK, JB .
AICHE JOURNAL, 1980, 26 (06) :1029-1038
[6]  
Fan L.S, 1989, GAS LIQUID SOLID FLU
[7]   PARTICLE-TO-LIQUID MASS-TRANSFER IN GAS-LIQUID-SOLID FLUIDIZATION [J].
FUKUMA, M ;
SATO, M ;
MUROYAMA, K ;
YASUNISHI, A .
JOURNAL OF CHEMICAL ENGINEERING OF JAPAN, 1988, 21 (03) :231-237
[8]   GAS-LIQUID MASS-TRANSFER IN FLUIDIZED PARTICLE BEDS [J].
NGUYENTIEN, K ;
PATWARI, AN ;
SCHUMPE, A ;
DECKWER, WD .
AICHE JOURNAL, 1985, 31 (02) :194-201
[9]   SOLID LIQUID MASS-TRANSFER IN 3-PHASE FIXED AND FLUIDIZED-BEDS [J].
NIKOV, I ;
DELMAS, H .
CHEMICAL ENGINEERING SCIENCE, 1987, 42 (05) :1089-1093
[10]  
PRAKASH A, 1984, 34TH P CAN CHEM ENG, P478