IMAGING OF THE RENAL-ARTERIES - VALUE OF MR ANGIOGRAPHY

被引:184
作者
DEBATIN, JF
SPRITZER, CE
GRIST, TM
BEAM, C
SVETKEY, LP
NEWMAN, GE
SOSTMAN, HD
机构
[1] DUKE UNIV,MED CTR,DEPT RADIOL,BOX 3808,DURHAM,NC 27710
[2] DUKE UNIV,MED CTR,DEPT MED,DURHAM,NC 27710
关键词
D O I
10.2214/ajr.157.5.1927823
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We compared the efficacy of MR angiography with that of conventional angiography for visualizing the renal arteries and detecting renovascular disease. Thirty-three MR angiographic studies, consisting of axial two-dimensional (2-D) phase-contrast, coronal 2-D phase-contrast, and coronal 2-D time-of-flight acquisitions, were performed within 48 hr of conventional arteriography. The studies were done to evaluate possible renovascular hypertension (n = 25) or potential donor nephrectomy (n = 8). The three MR image sets were interpreted independently, in random order by three observers, with regard to the number of renal arteries, degree of vessel visualization, arteriovenous overlap, and presence of renovascular disease. A fourth interpretation was based on the combined axial and coronal phase-contrast image sets. Evaluation was limited to the proximal 35 mm of each renal artery. Renal artery visualization and detection of renovascular disease were more complete with coronal phase-contrast (80% sensitivity, 91% specificity) than with time-of-flight (53% sensitivity, 97% specificity) images. Combined axial and coronal phase-contrast images permitted visualization of the proximal 35 mm of all dominant renal arteries and detection of 13 of 15 stenoses (87% sensitivity, 97% specificity). Our data suggest that biplanar MR angiography has considerable potential as a noninvasive screening technique for the evaluation of renovascular disease.
引用
收藏
页码:981 / 990
页数:10
相关论文
共 24 条
  • [1] MR ANGIOGRAPHY OF PERIPHERAL, CAROTID, AND CORONARY-ARTERIES
    ALFIDI, RJ
    MASARYK, TJ
    HAACKE, EM
    LENZ, GW
    ROSS, JS
    MODIC, MT
    NELSON, AD
    LIPUMA, JP
    COHEN, AM
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1987, 149 (06) : 1097 - 1109
  • [2] BLOOD-FLOW EFFECTS IN MAGNETIC-RESONANCE IMAGING
    AXEL, L
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1984, 143 (06) : 1157 - 1166
  • [3] BLOOD-FLOW IN THE CAROTID ARTERIES - QUANTIFICATION BY USING PHASE-SENSITIVE MR IMAGING
    BENDEL, P
    BUONOCORE, E
    BOCKISCH, A
    BESOZZI, MC
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1989, 152 (06) : 1307 - 1310
  • [4] RENAL-ARTERY STENOSIS - PROSPECTIVE EVALUATION OF DIAGNOSIS WITH COLOR DUPLEX US COMPARED WITH ANGIOGRAPHY - WORK IN PROGRESS
    BERLAND, LL
    KOSLIN, DB
    ROUTH, WD
    KELLER, FS
    [J]. RADIOLOGY, 1990, 174 (02) : 421 - 423
  • [5] BISHOP YMM, 1984, DISCRETE MULTIVARIAN, P258
  • [6] PATIENTS AT HIGH-RISK FOR RENAL-ARTERY STENOSIS - A SIMPLE METHOD OF RENAL SCINTIGRAPHIC ANALYSIS WITH TC-99M DTPA AND CAPTOPRIL
    CHEN, CC
    HOFFER, PB
    VAHJEN, G
    GOTTSCHALK, A
    KOSTER, K
    ZUBAL, IG
    SETARO, JF
    ROER, DA
    BLACK, HR
    [J]. RADIOLOGY, 1990, 176 (02) : 365 - 370
  • [7] 3-DIMENSIONAL PHASE-CONTRAST ANGIOGRAPHY
    DUMOULIN, CL
    SOUZA, SP
    WALKER, MF
    WAGLE, W
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1989, 9 (01) : 139 - 149
  • [8] PROJECTION ARTERIOGRAPHY AND VENOGRAPHY - INITIAL CLINICAL-RESULTS WITH MR
    EDELMAN, RR
    WENTZ, KU
    MATTLE, H
    ZHAO, B
    LIU, C
    KIM, D
    LAUB, G
    [J]. RADIOLOGY, 1989, 172 (02) : 351 - 357
  • [9] MR ANGIOGRAPHY
    EDELMAN, RR
    MATTLE, HP
    ATKINSON, DJ
    HOOGEWOUD, HM
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1990, 154 (05) : 937 - 946
  • [10] EVALUATION OF STEADY AND PULSATILE FLOW WITH DYNAMIC MRI USING LIMITED FLIP ANGLES AND GRADIENT REFOCUSED ECHOES
    EVANS, AJ
    HEDLUND, LW
    HERFKENS, RJ
    UTZ, JA
    FRAM, EK
    BLINDER, RA
    [J]. MAGNETIC RESONANCE IMAGING, 1987, 5 (06) : 475 - 482