DETERMINATION OF BAMBUTEROL, A PRODRUG OF TERBUTALINE, IN PLASMA AND URINE BY GAS-CHROMATOGRAPHY MASS-SPECTROMETRY

被引:19
作者
LINDBERG, C [1 ]
JONSSON, S [1 ]
PAULSON, J [1 ]
TUNEK, A [1 ]
机构
[1] AB DRACO, PHARMACOL LAB, S-22100 LUND, SWEDEN
来源
BIOMEDICAL AND ENVIRONMENTAL MASS SPECTROMETRY | 1990年 / 19卷 / 04期
关键词
D O I
10.1002/bms.1200190403
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
(R,S)‐Bambuterol was isolated from plasma and urine by solid‐phase extraction and analysed as its trimethylsilyl derivative by gas chromatography/chemical ionization mass spectrometry with ammonia as the reagent gas. Deuterium‐labelled bambuterol was used as internal standard. An esterase inhibitor was added to plasma to prevent hydrolysis of bambuterol in the plasma sample. Bambuterol could be measured in plasma down to 1 nmol l−1 with a within‐day variation of less than 5% (coefficient of variation). The lower limit of measurement in urine was judged to be 8 nmol l−1, a concentration at which the within‐day variation was 5.4% (coefficient of variation). Copyright © 1990 John Wiley & Sons, Ltd.
引用
收藏
页码:218 / 224
页数:7
相关论文
共 12 条
[1]   PHARMACOKINETIC EVALUATION IN MAN OF TERBUTALINE GIVEN AS SEPARATE ENANTIOMERS AND AS THE RACEMATE [J].
BORGSTROM, L ;
NYBERG, L ;
JONSSON, S ;
LINDBERG, C ;
PAULSON, J .
BRITISH JOURNAL OF CLINICAL PHARMACOLOGY, 1989, 27 (01) :49-56
[2]   ANALYSIS FOR CARBAMATE INSECTICIDES AND METABOLITES [J].
DOROUGH, HW ;
THORSTENSON, JH .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1975, 13 (05) :212-224
[3]   BAMBUTEROL - DOSE-RESPONSE STUDY OF A NEW TERBUTALINE PRODRUG IN ASTHMA [J].
HOLSTEINRATHLOU, NH ;
LAURSEN, LC ;
MADSEN, F ;
SVENDSEN, UG ;
GNOSSPELIUS, Y ;
WEEKE, B .
EUROPEAN JOURNAL OF CLINICAL PHARMACOLOGY, 1986, 30 (01) :7-11
[4]   DETERMINATION OF TERBUTALINE IN PLASMA BY GAS-CHROMATOGRAPHY CHEMICAL IONIZATION MASS-SPECTROMETRY [J].
JACOBSSON, SE ;
JONSSON, S ;
LINDBERG, C ;
SVENSSON, LA .
BIOMEDICAL MASS SPECTROMETRY, 1980, 7 (06) :265-268
[5]   QUANTITATIVE-DETERMINATION OF TERBUTALINE IN HUMAN-PLASMA AFTER ADMINISTRATION OF BAMBUTEROL USING COUPLED COLUMNS AND ELECTROCHEMICAL DETECTION [J].
KENNEDY, BM ;
BLOMGREN, A ;
EDHOLM, LE ;
ROOS, C .
CHROMATOGRAPHIA, 1987, 24 :895-899
[6]  
LINDBERG C, 1989, DRUG METAB DISPOS, V17, P311
[7]   LIQUID SOLID SAMPLE PREPARATION IN DRUG ANALYSIS [J].
MCDOWALL, RD ;
PEARCE, JC ;
MURKITT, GS .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1986, 4 (01) :3-21
[8]   NEW LIPOPHILIC TERBUTALINE ESTER PRODRUGS WITH LONG EFFECT DURATION [J].
OLSSON, OAT ;
SVENSSON, LA .
PHARMACEUTICAL RESEARCH, 1984, (01) :19-23
[9]   BAMBUTEROL - CLINICAL EFFECTS OF DIFFERENT DOSES OF A LONG-ACTING BRONCHODILATOR PRODRUG [J].
SANDSTROM, T ;
ASANDER, L ;
CLEMMENSEN, IH ;
EKLUND, G ;
GNOSSPELIUS, Y ;
PEDERSEN, BK ;
PERSSON, G ;
RAVN, S ;
ROSENHALL, L ;
WEEKE, B .
RESPIRATION, 1988, 53 (01) :31-36
[10]   THE DESIGN AND BIOACTIVATION OF PRESYSTEMICALLY STABLE PRODRUGS [J].
SVENSSON, LA ;
TUNEK, A .
DRUG METABOLISM REVIEWS, 1988, 19 (02) :165-194