A CDTE GAMMA-RAY SPECTROMETER WITH IMAGING CAPABILITIES FOR ASTROPHYSICS - MONTE-CARLO SIMULATION RESULTS

被引:9
作者
CAROLI, E
BALDAZZI, G
DICOCCO, G
DONATI, A
DUSI, W
MALAGUTI, G
ROSSI, M
STEPHEN, JB
机构
[1] UNIV BOLOGNA,DIPARTIMENTO FIS,I-40126 BOLOGNA,ITALY
[2] UNIV BOLOGNA,DIPARTIMENTO ASTRON,I-40126 BOLOGNA,ITALY
关键词
D O I
10.1016/0168-9002(92)91245-5
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
One of the critical design constraints for satellite-borne gamma-ray astronomy telescopes incorporating solid-state (mainly Ge) detectors has been the problem of keeping the detection plane at a very low temperature. This problem should be alleviated by the considerable progress being made in the technology of room temperature devices such as CdTe detectors. Furthermore. a new geometrical arrangement in the design of these particular detectors allows the use of small devices (mu-detectors) with high detection efficiency and good spectroscopic performance (E/DELTAE approximately 100). These mu-detectors can be mosaiced in order to form a large area position sensitive detector (PSD) with fine spatial resolution (about a few millimeters). Such a PSD could be coupled with a coded aperture to realise a telescope for use in high energy astronomy (0.05-5 MeV). Herein we give preliminary results from a Monte Carlo simulation of such a PSD concerning the detection efficiency and spatial resolution as a function of photon energy and incident angle. The results suggest that CdTe is a promising new detection medium for use in high energy astronomy.
引用
收藏
页码:639 / 643
页数:5
相关论文
共 16 条
[1]  
[Anonymous], 1968, SEMICONDUCTOR DETECT
[2]  
BALDAZZI G, 1991, 1991 IEEE NUCL SCI S
[3]  
BRUN R, 1991, GEANT3 USER MANUAL
[4]   CODED APERTURE IMAGING IN X-RAY AND GAMMA-RAY ASTRONOMY [J].
CAROLI, E ;
STEPHEN, JB ;
DICOCCO, G ;
NATALUCCI, L ;
SPIZZICHINO, A .
SPACE SCIENCE REVIEWS, 1987, 45 (3-4) :349-403
[5]  
CAROLI E, 1991, 22ND P INT COSM RAY
[6]  
COURVOISIER TJL, 1991, ESANASA SCI911 REP
[7]  
DEAN AJ, 1991, SPACE SCI REV, V57, P109, DOI 10.1007/BF00195952
[8]   STATUS OF SEMIINSULATING CADMIUM TELLURIDE FOR NUCLEAR RADIATION DETECTORS [J].
HAGEALI, M ;
SIFFERT, P .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1992, 322 (03) :313-323
[9]  
Knoll G.F., 1989, RAD DETECTION MEASUR
[10]  
Mahoney W.A., 1988, AIPC, V170, P149