HYDROXYL RADICAL OXIDATION PROCESSES FOR THE REMOVAL OF TRIAZINE FROM NATURAL-WATER

被引:27
作者
PRADOS, M
PAILLARD, H
ROCHE, P
机构
[1] Anjou Recherche, Compagnie Générale des Eaux Research Center, 78603 Maisons Laffite Cedex, Chemin de la Digue
关键词
OZONE; OXIDATION; FLOCCULATION; RADICAL FORMATION; TRIAZINES; FENTONS REAGENT; FE2+ H2O2 TREATMENT; OZONE HYDROGEN PEROXIDE TREATMENT; UV OZONE TREATMENT; ADVANCED OXIDATION PROCESSES; ATRAZINE; SIMAZINE; ENDOSULFAN;
D O I
10.1080/01919519508547545
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The purpose of this study was to point out processes that can provide triazine oxidation via hydroxyl radical production in a water treatment line. We focus our attention on: oxido-flocculation, using Fe2+, H2O2 inter-oxidation, using O-3, H2O2 and eventually an heterogeneous catalyst. disinfection, using UV, O-3 and H2O2 combinations. Results show that triazines can be removed by all these processes with different efficiencies. At full scale, the O-3/H2O2 process presents the best performances from an economical and technical point of view.
引用
收藏
页码:183 / 194
页数:12
相关论文
共 15 条
[1]  
AGUIAR A, 1992, SEP C SPEC POLL REC
[2]  
BARB WG, 1990, NATURE, V163, P692
[3]  
CARBONNIER F, 1991, ESSAIS FENTON FE3 PL
[4]  
DENIS M, 1991, 10TH P OZ WORLD C PA, V1, P241
[5]  
DEVALASQUEZ O, 1992, THESIS U RENNES
[6]  
Dore M., 1989, CHIMIE OXYDANTS TRAI
[7]   Colorimetric determination of hydrogen peroxide [J].
Eisenberg, GM .
INDUSTRIAL AND ENGINEERING CHEMISTRY-ANALYTICAL EDITION, 1943, 15 :327-328
[8]  
HART J, 1989, U1005 WAT RES CTR RE
[9]  
HOTELIER J, 1992, SEP C IWSA AIDE AMST
[10]  
Jefcoate C.R.E., 1969, J CHEM SOC B, P1013