A SPOILING SEQUENCE FOR SUPPRESSION OF RESIDUAL TRANSVERSE MAGNETIZATION

被引:19
作者
WANG, HZ [1 ]
RIEDERER, SJ [1 ]
机构
[1] DUKE UNIV,MED CTR,DEPT RADIOL,DURHAM,NC 27710
关键词
D O I
10.1002/mrm.1910150202
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We present a spoiler sequence which substantially eliminates residual transverse magnetization in rapid magnetic resonance imaging. Such magnetization is due to the repetition time TR being on the order of or shorter than the transverse relaxation time T2. This sequence was designed using computer simulation methods to model the slice profile and signal. The spoiler pulse is applied in the slice‐selecting direction and the magnitude of the gradient spoiler is incremented with each repetition as an arithmetic series. A finite number of different spoiler amplitudes is repeated with a cycle time several times greater than the anticipated T2. Each spoiler is shown to nullify the residual transverse magnetization from the just‐measured signal of the experiment as well as that from preceding repetitions. It is shown experimentally that the spoiler pulse can be as short as 2 ms. This is considerably shorter than existing methods using constant spoiling or phase‐tagged spoiling. This sequence was used to acquire. T1‐weighted images free of the central line artifact of FLASH imaging. Furthermore, images formed with the new spoiled technique are shown to have contrast‐to‐noise comparable if not superior to standard T 1‐weighted spin‐echo images while taking only a fifth of the scan time. © 1990 Academic Press, Inc. Copyright © 1990 Wiley‐Liss, Inc., A Wiley Company
引用
收藏
页码:175 / 191
页数:17
相关论文
共 15 条
[1]   ELIMINATION OF TRANSVERSE COHERENCES IN FLASH MRI [J].
CRAWLEY, AP ;
WOOD, ML ;
HENKELMAN, RM .
MAGNETIC RESONANCE IN MEDICINE, 1988, 8 (03) :248-260
[2]  
DARRASSE L, 1986, SMRM MONTREAL, P944
[3]   TRANSVERSE COHERENCE IN RAPID FLASH NMR IMAGING [J].
FRAHM, J ;
HANICKE, W ;
MERBOLDT, KD .
JOURNAL OF MAGNETIC RESONANCE, 1987, 72 (02) :307-314
[4]   RAPID CALCULATION OF T1 USING VARIABLE FLIP ANGLE GRADIENT REFOCUSED IMAGING [J].
FRAM, EK ;
HERFKENS, RJ ;
JOHNSON, GA ;
GLOVER, GH ;
KARIS, JP ;
SHIMAKAWA, A ;
PERKINS, TG ;
PELC, NJ .
MAGNETIC RESONANCE IMAGING, 1987, 5 (03) :201-208
[5]   PHASE AND INTENSITY ANOMALIES IN FOURIER TRANSFORM NMR [J].
FREEMAN, R ;
HILL, HDW .
JOURNAL OF MAGNETIC RESONANCE, 1971, 4 (03) :366-&
[6]   NEW LOOK AT METHOD OF VARIABLE NUTATION ANGLE FOR MEASUREMENT OF SPIN-LATTICE RELAXATION-TIMES USING FOURIER-TRANSFORM NMR [J].
GUPTA, RK .
JOURNAL OF MAGNETIC RESONANCE, 1977, 25 (01) :231-235
[7]  
HAASE A, 1986, J MAGN RESON, V67, P217
[8]   DRIVEN-EQUILIBRIUM SINGLE-PULSE OBSERVATION OF T1 RELAXATION - A REEVALUATION OF A RAPID NEW METHOD FOR DETERMINING NMR SPIN-LATTICE RELAXATION-TIMES [J].
HOMER, J ;
BEEVERS, MS .
JOURNAL OF MAGNETIC RESONANCE, 1985, 63 (02) :287-297
[9]   NEW METHOD FOR MEASURING LONGITUDINAL RELAXATION-TIMES [J].
MCDONALD, GG ;
LEIGH, JS .
JOURNAL OF MAGNETIC RESONANCE, 1973, 9 (03) :358-362
[10]   3-DIMENSIONAL NMR IMAGING USING SELECTIVE EXCITATION [J].
SUTHERLAND, RJ ;
HUTCHISON, JMS .
JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1978, 11 (01) :79-83