A STUDY OF AUTOLOGOUS BLOOD COLLECTED AFTER JOINT REPLACEMENT SURGERY

被引:6
作者
ROBBINS, G
GRECH, H
HOWES, K
机构
[1] Department of Haematology, Royal Surrey County Hospital, Guildford
关键词
D O I
10.1111/j.1423-0410.1992.tb01189.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Blood from the surgical drains of 11 patients undergoing joint replacement was collected in the Solcotrans Orthopaedic autologous transfusion device and analysed for microparticulate matter before and after micro-aggregate filtration and for its effect on the coagulation of paired venous blood samples. An average of 165 ml (range 0-260 ml) was collected into the Solcotrans during the first hour. Using a Coulter Counter Zm particle counter, particulate matter of diameter 10-20-mu-m was found in only 2 of 10 collections at an average concentration of 33 x 10(3)/l. All units contained acoagulable blood [kaolin partial thromboplastin time (KPTT) > 600 s] but when mixed with paired post-operative venous samples exhibited the ability to shorten the KPTT by an average of 4.3 s in spite of the marked dilutional effect of mixing. Retransfusion of blood collected in the Solcotrans Orthopaedic device appears to be a suitable method to supplement or substitute pre-deposit and reduce exposure to homologous blood. Given the low incidence and concentration of microparticles detected, retransfusion of shed blood by this method is unlikely to cause significant pulmonary vascular occlusion resulting directly from deposition of microparticles.
引用
收藏
页码:152 / 155
页数:4
相关论文
共 8 条
[1]   FATAL LUNG-SCAN IN A CASE OF PULMONARY-HYPERTENSION DUE TO OBLITERATIVE PULMONARY VASCULAR-DISEASE [J].
CHILD, JS ;
WOLFE, JD ;
TASHKIN, D ;
NAKANO, F .
CHEST, 1975, 67 (03) :308-310
[2]   UNWASHED FILTERED SHED BLOOD COLLECTED AFTER KNEE AND HIP ARTHROPLASTIES - A SOURCE OF AUTOLOGOUS RED-BLOOD-CELLS [J].
FARIS, PM ;
RITTER, MA ;
KEATING, EM ;
VALERI, CR .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1991, 73A (08) :1169-1178
[3]   FATAL FAT EMBOLISM FOLLOWING REPLACEMENT ARTHROPLASTY FOR TRANSCERVICAL FRACTURES OF FEMUR [J].
GRESHAM, GA ;
KUCZYNSKI, A ;
ROSBOROUGH, D .
BMJ-BRITISH MEDICAL JOURNAL, 1971, 2 (5762) :617-+
[4]  
HAGEMAN JR, 1981, CLIN CHEST MED, V6, P503
[5]  
HERMANN HJ, 1982, NUKLEARMEDIZIN
[6]   LIPOSYN INFUSION INCREASES PLASMA PROSTAGLANDIN CONCENTRATIONS [J].
HUNT, CE ;
PACHMAN, LM ;
HAGEMAN, JR ;
COBB, MA ;
KLEMKA, L .
PEDIATRIC PULMONOLOGY, 1986, 2 (03) :154-158
[7]   FATALITY IMMEDIATELY FOLLOWING RAPID INFUSION OF MACROAGGREGATES OF 99MTC ALBUMIN (MAA) FOR LUNG SCAN [J].
VINCENT, WR ;
GOLDBERG, SJ ;
DESILETS, D .
RADIOLOGY, 1968, 91 (06) :1181-+
[8]   DEATH FOLLOWING INJECTION OF LUNG-SCANNING AGENT IN A CASE OF PULMONARY-HYPERTENSION [J].
WILLIAMS, JO .
BRITISH JOURNAL OF RADIOLOGY, 1974, 47 (553) :61-63