CEREBRAL BLOOD OXYGENATION IN RAT-BRAIN DURING HYPOXIC HYPOXIA - QUANTITATIVE MRI OF EFFECTIVE TRANSVERSE RELAXATION RATES

被引:60
作者
PRIELMEIER, F
NAGATOMO, Y
FRAHM, J
机构
[1] Biomedizinische NMR Forschungs GmbH, Max-Planck-lnstitut für biophysikalische Chemie, Göttingen
关键词
RAT; BRAIN; MR; OXYGENATION; HYPOXIA;
D O I
10.1002/mrm.1910310615
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Oxygenation-sensitive MRI of respiratory challenges in the brain of experimental animals will considerably benefit from a quantitative relationship between cerebral blood oxygenation and MRI parameters. Here, a multi-echo gradient-echo MRI technique was used to determine effective transverse relaxation rates R(2)(*) = 1/T-2(*) of rat brain in vivo during short periods of hypoxia and interleaved normoxic phases. The differential contribution Delta R(2)(*) observed during hypoxia was found to increase linearly with arterial blood deoxygenation for mild to moderate conditions. Severe deoxygenation resulted in a plateau most likely due to enhanced cerebral blood flow.
引用
收藏
页码:678 / 681
页数:4
相关论文
共 10 条
[1]   RELATIONSHIP BETWEEN ARTERIAL PO2 AND CEREBRAL BLOOD-FLOW IN HYPOXIC HYPOXIA [J].
BORGSTROM, L ;
JOHANNSSON, H ;
SIESJO, BK .
ACTA PHYSIOLOGICA SCANDINAVICA, 1975, 93 (03) :423-432
[2]  
DECRESPIGNY AJ, 1992, MAGN RESON MED, V27, P391, DOI 10.1002/mrm.1910270220
[3]  
HOPPEL BR, 1992, 11TH P SMRM ANN M BE, P713
[4]   BLOOD-FLOW AND OXYGEN-CONSUMPTION OF RAT-BRAIN IN PROFOUND HYPOXIA [J].
JOHANNSSON, H ;
SIESJO, BK .
ACTA PHYSIOLOGICA SCANDINAVICA, 1974, 90 (01) :281-282
[5]  
LEBIHAN D, 1993, FUNCTIONAL MRI BRAIN
[6]   ACUTE STROKE IN CATS - COMPARISON OF DYNAMIC SUSCEPTIBILITY-CONTRAST MR-IMAGING WITH T2-WEIGHTED AND DIFFUSION-WEIGHTED MR-IMAGING [J].
MAEDA, M ;
ITOH, S ;
IDE, H ;
MATSUDA, T ;
KOBAYASHI, H ;
KUBOTA, T ;
ISHII, Y .
RADIOLOGY, 1993, 189 (01) :227-232
[7]   THE SENSITIVITY OF MAGNETIC-RESONANCE IMAGE SIGNALS OF A RAT-BRAIN TO CHANGES IN THE CEREBRAL VENOUS-BLOOD OXYGENATION [J].
OGAWA, S ;
LEE, TM ;
BARRERE, B .
MAGNETIC RESONANCE IN MEDICINE, 1993, 29 (02) :205-210
[8]   OXYGENATION-SENSITIVE CONTRAST IN MAGNETIC-RESONANCE IMAGE OF RODENT BRAIN AT HIGH MAGNETIC-FIELDS [J].
OGAWA, S ;
LEE, TM ;
NAYAK, AS ;
GLYNN, P .
MAGNETIC RESONANCE IN MEDICINE, 1990, 14 (01) :68-78
[9]   DYNAMIC HIGH-RESOLUTION MR-IMAGING OF BRAIN DEOXYGENATION DURING TRANSIENT ANOXIA IN THE ANESTHETIZED RAT [J].
PRIELMEIER, F ;
MERBOLDT, KD ;
HANICKE, W ;
FRAHM, J .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1993, 13 (05) :889-894
[10]   ECHO-PLANAR TIME COURSE MRI OF CAT BRAIN OXYGENATION CHANGES [J].
TURNER, R ;
LEBIHAN, D ;
MOONEN, CTW ;
DESPRES, D ;
FRANK, J .
MAGNETIC RESONANCE IN MEDICINE, 1991, 22 (01) :159-166