DETERMINANTS OF VENTRICULAR DEFIBRILLATION IN ADULTS

被引:64
作者
GASCHO, JA
CRAMPTON, RS
CHERWEK, ML
SIPES, JN
HUNTER, FP
OBRIEN, WM
机构
[1] UNIV VIRGINIA,CTR MED,DIV CARDIOL,CHARLOTTESVILLE,VA 22908
[2] UNIV VIRGINIA,MED CTR,EMERGENCY MED SERV,CHARLOTTESVILLE,VA 22903
[3] UNIV VIRGINIA,MED CTR,DIV BIOMED ENGN,CHARLOTTESVILLE,VA 22903
[4] UNIV VIRGINIA,MED CTR,DIV BIOMET,CHARLOTTESVILLE,VA 22903
关键词
D O I
10.1161/01.CIR.60.2.231
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Conventional defibrillators which stored no more than 400 J and used damped sine wave pulses defibrillated 240 of 253 (95%) episodes of ventricular fibrillation (VF) in 94 prospectively assessed resuscitations in 88 adults. Shocks of 80-240 J (under 3 J/kg) delivered to the chest wall defibrillated more often than higher energy levels. Defibrillation rate did not correlate with weight. Defibrillation was determined by the diagnosis and setting in which VF occurred. Patients with acute myocardial infarction (AMI) and primary VF or with coronary disease and no AMI defibrillated more easily than patients with AMI and secondary VF or with no coronary disease. VF in a terminal patient (agonal VF) defibrillated less often than VF in other clinical situations. Age, weight, delivered energy, duration of pulse wave, and duration of VF had little, if any, influence on rate of defibrillation. These data fail to support the use of more expensive, high-output defibrillators sold by 11 of 14 American manufacturers.
引用
收藏
页码:231 / 240
页数:10
相关论文
共 39 条
[1]   EFFICACY OF TRAPEZOIDAL WAVE FORMS FOR VENTRICULAR DEFIBRILLATION [J].
ANDERSON, GJ ;
SUELZER, J .
CHEST, 1976, 70 (02) :298-300
[2]   VENTRICULAR FIBRILLATION OF LONG DURATION ABOLISHED BY ELECTRIC SHOCK [J].
BECK, CS ;
PRITCHARD, WH ;
FEIL, HS .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1947, 135 (15) :985-986
[3]  
BELLET S, 1971, CLIN DISORDERS HEART, P1222
[4]   TRANSTHORACIC VENTRICULAR DEFIBRILLATION IN ADULTS [J].
CAMPBELL, NPS ;
WEBB, SW ;
ADGEY, AAJ ;
PANTRIDGE, JF .
BRITISH MEDICAL JOURNAL, 1977, 2 (6099) :1379-1381
[5]  
COLLINS RE, 1978, MED INSTRUM, V12, P53
[6]   MYOCARDIAL UPTAKE OF TECHNETIUM-99M STANNOUS PYROPHOSPHATE FOLLOWING DIRECT-CURRENT TRANSTHORACIC COUNTERSHOCK [J].
DICOLA, VC ;
FREEDMAN, GS ;
DOWNING, SE ;
ZARET, BL .
CIRCULATION, 1976, 54 (06) :980-986
[7]  
FLEMING JS, 1974, LECTURE NOTES CARDIO, P103
[8]   MYOCARDIAL INFARCTION 1972 - SYMPOSIUM .1. INTRODUCTION [J].
FRIEDBERG, CK .
CIRCULATION, 1972, 45 (01) :179-+
[9]   MEGAWATT DEFIBRILLATOR FOR TRANSCHEST DEFIBRILLATION OF HEAVY SUBJECTS [J].
GEDDES, LA ;
BOURLAND, JD ;
COULTER, TW ;
CANTRELL, G ;
MOORE, AG ;
VASKU, J ;
CABLER, P ;
TACKER, WA .
MEDICAL & BIOLOGICAL ENGINEERING, 1973, 11 (06) :747-754
[10]  
GEDDES LA, 1978, MED INSTRUM, V12, P11