FULLY AUTOMATED HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC ASSAY FOR THE ANALYSIS OF FREE CATECHOLAMINES IN URINE

被引:14
作者
SAID, R
ROBINET, D
BARBIER, C
SARTRE, J
HUGUET, C
机构
[1] Laboratoire Cerba, Cergy Pontoise Cedex
来源
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS | 1990年 / 530卷 / 01期
关键词
D O I
10.1016/S0378-4347(00)82297-5
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A totally automated and reliable high-performance liquid chromatographic method is described for the routine determination of free catecholamines (norepinephrine, epinephrine and dopamine) in urine. The catecholamines were isolated from urine samples using small alumina columns. A standard automated method for pH adjustment of urine before the extraction step has been developed. The extraction was performed on an ASPEC (Automatic Sample Preparation with Extraction Columns, Gilson). The eluate was collected in a separate tube and then automatically injected into the chromatographic column. The catecholamines were separated by reversed-phase ion-pair liquid chromatography and quantified by fluorescence detection. No manual intervention was required during the extraction and separation procedure. One sample may be run every 15 min, ca. 96 samples in 24 h. Analytical recoveries for all three catecholamines are 63-87%, and the detection limits are 0.01, 0.01, and 0.03 μM for norepinephrine, epinephrine and dopamine, respectively, which is highly satisfactory for urine. Day-to-day coefficients of variation were less than 10%. © 1990.
引用
收藏
页码:11 / 18
页数:8
相关论文
共 23 条
[1]  
ANDERSON GM, 1981, CLIN CHEM, V27, P2060
[2]   LIQUID-CHROMATOGRAPHIC DETERMINATION OF URINARY CATECHOLAMINES AFTER ONE-STEP ALUMINA EXTRACTION [J].
ANDERSON, GM ;
DURKIN, TA ;
MORTON, JB ;
COHEN, DJ .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1988, 424 (02) :373-377
[3]  
ANTON AH, 1962, J PHARMACOL EXP THER, V138, P360
[4]   DETERMINATION OF CATECHOLAMINES IN URINE (AND PLASMA) BY LIQUID-CHROMATOGRAPHY AFTER ONLINE SAMPLE PRETREATMENT ON SMALL ALUMINA OR DIHYDROXYBORYLSILICA COLUMNS [J].
DEJONG, J ;
POINT, AJF ;
TJADEN, UR ;
BEEKSMA, S ;
KRAAK, JC .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1987, 414 (02) :285-300
[5]  
EISENHOFER G, 1986, CLIN CHEM, V32, P2030
[6]   DETERMINATION OF CATECHOLAMINES IN URINE BY ION-EXCHANGE LIQUID-CHROMATOGRAPHY WITH ELECTROCHEMICAL DETECTION [J].
ERIKSSON, BM ;
GUSTAFSSON, S ;
PERSSON, BA .
JOURNAL OF CHROMATOGRAPHY, 1983, 278 (02) :255-263
[7]   MICRO HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC SYSTEM WITH MICRO PRECOLUMN AND DUAL ELECTROCHEMICAL DETECTOR FOR DIRECT INJECTION-ANALYSIS OF CATECHOLAMINES IN BODY-FLUIDS [J].
GOTO, M ;
NAKAMURA, T ;
ISHII, D .
JOURNAL OF CHROMATOGRAPHY, 1981, 226 (01) :33-42
[8]   AN AUTOMATED-METHOD FOR THE ANALYSIS OF URINARY FREE CATECHOLAMINES USING ASTED AND HIGH-PRESSURE LIQUID-CHROMATOGRAPHY [J].
GREEN, B ;
COOPER, JDH ;
TURNELL, DC .
ANNALS OF CLINICAL BIOCHEMISTRY, 1989, 26 :361-367
[9]   ISOLATION OF CATECHOLAMINES IN BIOLOGICAL-FLUIDS BY BORIC-ACID GEL [J].
HIGA, S ;
SUZUKI, T ;
HAYASHI, A ;
TSUGE, I ;
YAMAMURA, Y .
ANALYTICAL BIOCHEMISTRY, 1977, 77 (01) :18-24
[10]   THE ESTIMATION OF CATECHOLAMINES IN HUMAN-PLASMA [J].
HOLLY, JMP ;
MAKIN, HLJ .
ANALYTICAL BIOCHEMISTRY, 1983, 128 (02) :257-274