LONG-TERM PERFORMANCE OF EPIMYOCARDIAL PACING LEADS IN ADULTS - COMPARISON WITH ENDOCARDIAL LEADS

被引:8
作者
HELGUERA, ME
MALONEY, JD
WOSCOBOINIK, JR
TROHMAN, RG
MCCARTHY, PM
MORANT, VA
WILKOFF, BL
CASTLE, LW
PINSKI, SL
机构
[1] Department of Cardiology, Cleveland, Ohio
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 1993年 / 16卷 / 03期
关键词
CARDIAC PACING; PACING ELECTRODES; EPICARDIAL ELECTRODES;
D O I
10.1111/j.1540-8159.1993.tb01603.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The long-term performance of epimyocardial pacing leads in children is well established, but few studies have analyzed the performance in adults. This issue has clinical relevance in view of the increased use of epimyocardial leads with implantable cardioverter defibrillator and antitachycardia pacing systems. We analyzed 93 epimyocardial pacing ''systems'' (121 leads: 65 unipolar, 28 bipolar) in adult patients (age 57 +/- 16 years), implanted since January 1980. Two different models were studied: Medtronic 4951 ''Stab-on'' (n = 35) and Medtronic 6917/6917A ''Screw-in'' (n = 58). A control group was created by randomly matching each epimyocardial system with two endocardial leads, according to age and year of implant. Epimyocardial and endocardial leads were followed-up for 44 +/- 35 and 43 +/- 35 months, respectively (P = NS). Freedom from failure for epimyocardial leads was 0.91 (95% Confidence Interval [95% CI] = 0.82 to 0.96) at 5 years, and 0.91 (95% CI = 0.69 to 0.98) at 10 years. No difference was found between the two analyzed models. Freedom from failure for endocardial leads was 0.97 (95% CI = 0.93 to 0.99) and 0.90 (95% CI = 0.61 to 0.97) at 5 and 10 years, respectively. Epimyocardial leads had a significantly poorer short-term survival than endocardial leads, secondarily to earlier ''technique related'' failures (P = 0.03; relative risk 3.0; Wilcoxon test). However, overall long-term performance was similar to endocardial leads. Epimyocardial pacing leads, meticulously implanted and tested, have a long-term performance similar to endocardial pacing leads.
引用
收藏
页码:412 / 417
页数:6
相关论文
共 22 条
  • [1] COMPARISON OF THE SUTURELESS AND SUTURE-TYPE EPICARDIAL ELECTRODES IN PEDIATRIC CARDIAC PACING
    DELEON, SY
    ILBAWI, MN
    KOSTER, N
    IDRISS, FS
    [J]. ANNALS OF THORACIC SURGERY, 1982, 33 (03) : 273 - 276
  • [2] DELEON SY, 1990, J THORAC CARDIOV SUR, V99, P905
  • [3] 6-YEAR CLINICAL-EXPERIENCE WITH THE AUTOMATIC IMPLANTABLE CARDIOVERTER DEFIBRILLATOR
    EDEL, TB
    MALONEY, JD
    MOORE, S
    MCGUINN, WP
    GOHN, D
    WILLIAMS, D
    WILKOFF, BL
    MCCARTHY, P
    MORANT, VA
    PEARCE, G
    SIMMONS, TW
    TROHMAN, R
    FIRSTENBERG, M
    CASTLE, LW
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1991, 14 (11): : 1850 - 1854
  • [4] RISKS AND BENEFITS OF CARDIAC PACING IN CHILDREN
    ENNKER, J
    STEGMANN, T
    LUHMER, I
    OELERT, H
    [J]. INTERNATIONAL JOURNAL OF CARDIOLOGY, 1985, 8 (02) : 125 - 134
  • [5] PERMANENT PACEMAKER THERAPY IN CORRECTED TRANSPOSITION OF THE GREAT-ARTERIES - ANALYSIS OF SITE OF LEAD PLACEMENT IN 40 PATIENTS
    ESTES, NAM
    SALEM, DN
    ISNER, JM
    GAMBLE, WJ
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1983, 52 (08) : 1091 - 1097
  • [6] 16 FAILURES IN A SINGLE MODEL OF BIPOLAR POLYURETHANE-INSULATED VENTRICULAR PACING LEAD - A 44-MONTH EXPERIENCE
    HANSON, JS
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1984, 7 (03): : 389 - 394
  • [7] SIGNIFICANCE TESTING IN THE COMPARISON OF SURVIVAL CURVES FROM CLINICAL-TRIALS OF CANCER-TREATMENT
    HAYBITTLE, JL
    [J]. EUROPEAN JOURNAL OF CANCER & CLINICAL ONCOLOGY, 1986, 22 (11): : 1279 - 1283
  • [8] HAYES DL, 1983, J THORAC CARDIOV SUR, V85, P618
  • [9] HOOK BG, 1991, J AM COLL CARDIOL, V17, P985
  • [10] IMPROVED CHRONIC EPICARDIAL PACING IN CHILDREN - STEROID CONTRIBUTION TO POROUS PLATINIZED ELECTRODES
    KARPAWICH, PP
    HAKIMI, M
    ARCINIEGAS, E
    CAVITT, DL
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1992, 15 (08): : 1151 - 1157