A NOVEL SIGNAL-PROCESSING SCHEME FOR A FLUORESCENCE BASED FIBEROPTIC TEMPERATURE SENSOR

被引:36
作者
ZHANG, ZY
GRATTAN, KTV
PALMER, AW
机构
[1] Measurement and Instrumentation Centre, Department of Electrical, Electronic and Information Engineering, City University, London EC1V OHB, Northampton Square
关键词
D O I
10.1063/1.1142414
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A novel signal processing approach, which results in a significant improvement in the measurement resolution for a fluorescent decay-time-based fiber optic temperature sensor, is proposed. The technique discussed is based on the phase sensitive detection (lock-in) of the fluorescent signal. As with the other phase-sensitive detection techniques, it has the significant advantage of a high noise-suppression ability, but it differs from existing phase sensitive detection methods in several aspects which are discussed to yield this improvement. When the system is used to monitor the fluorescence lifetime of ruby, in the range from 40-degrees-C to 100-degrees-C, the measurement resolution achievable due to the signal processing scheme is +/- 0.04-degrees-C, and from 100-degrees-C to 200-degrees-C, it is +/- 0.2-degrees-C. It should be noted that other measurement errors must be reduced to achieve a high accuracy of measurement comparable with this. Finally, the proposed technique can be used not only for the monitoring of fluorescence lifetime, but also for the highly accurate monitoring of the time-constants of other appropriate first order systems, such as a capacitive sensor, operating under high noise conditions.
引用
收藏
页码:1735 / 1742
页数:8
相关论文
共 12 条
[1]   VISIBLE-LED PUMPED FIBER-OPTIC TEMPERATURE SENSOR [J].
AUGOUSTI, AT ;
GRATTAN, KTV ;
PALMER, AW .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1988, 37 (03) :470-472
[2]  
Best RE., 1984, PHASE LOCKED LOOPS T
[3]  
BOSSELMANN T, 1984, 2ND P OPT FIB SENS C, P151
[4]   PROBE DESIGN ASPECTS OF RUBY DECAY-TIME FLUORESCENT SENSORS [J].
GHASSEMLOOY, Z ;
GRATTAN, KTV ;
LYNCH, D .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1989, 60 (01) :87-89
[5]   A MINIATURIZED MICROCOMPUTER-BASED NEODYMIUM DECAY-TIME TEMPERATURE SENSOR [J].
GRATTAN, KTV ;
PALMER, AW ;
WILLSON, CA .
JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1987, 20 (10) :1201-1205
[6]   DEVELOPMENT OF A HIGH-TEMPERATURE FIBEROPTIC THERMOMETER PROBE USING FLUORESCENT DECAY [J].
GRATTAN, KTV ;
PALMER, AW ;
ZHANG, Z .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1991, 62 (05) :1210-1213
[7]   RUBY DECAY-TIME FLUORESCENCE THERMOMETER IN A FIBER-OPTIC CONFIGURATION [J].
GRATTAN, KTV ;
SELLI, RK ;
PALMER, AW .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1988, 59 (08) :1328-1335
[8]  
Lakowicz J., 1983, PRINCIPLE FLUORESCEN, p[96, 141, 239]
[9]   REMOTE OPTICAL MEASUREMENT OF TEMPERATURE USING LUMINESCENT MATERIALS [J].
MCCORMACK, JS .
ELECTRONICS LETTERS, 1981, 17 (18) :630-631
[10]  
MUNROE DM, 1982, SIGNAL NOISE RATIO I, V1, P455