COMPARATIVE-EVALUATION OF SUPPLEMENTAL HEPATITIS-C VIRUS-ANTIBODY TEST SYSTEMS

被引:32
作者
EVANS, CS
TOBLER, L
POLITO, A
STEWART, J
CHIEN, D
WILBER, J
QUAN, S
DELANEY, S
KUO, G
BUSCH, MP
机构
[1] IRWIN MEM BLOOD CTR,DEPT MED,270 MASONIC AVE,SAN FRANCISCO,CA 94118
[2] ABBOTT LABS,DIV DIAGNOST,AIDS TECH PROD DEV,ABBOTT PK,IL
[3] CHIRON CORP,HCV RES,EMERYVILLE,CA
[4] CHIRON CORP,NUCLEIC ACIDS CHEM,EMERYVILLE,CA
[5] ABBOTT LABS,VIROL REFERENCE LAB,ABBOTT PK,IL
[6] UNIV CALIF SAN FRANCISCO,DEPT LAB MED,SAN FRANCISCO,CA 94143
[7] CHIRON CORP,DIAGNOST DEV,EMERYVILLE,CA
[8] IRWIN MEM BLOOD CTR,SCI SERV,SAN FRANCISCO,CA
关键词
D O I
10.1046/j.1537-2995.1992.32592327712.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Implementation of routine blood donor screening using anti-hepatitis C virus (HCV) enzyme immunoassay (EIA) has resulted in an urgent need for well-characterized supplemental assays to confirm the presence of HCV antibodies. A comparative study of four commercially available supplemental assays is reported here: first- and second-generation versions of a strip recombinant immunoblot assay (RIBA-1 and RIBA-2), an HCV neutralization EIA, and HCV neutralization plus synthetic peptide EIA. Three hundred sixty-seven blood donor specimens that were repeatedly reactive on HCV EIA were studied. Most specimens (93%) were also evaluated by radioimmunoassay (RIA) with a six-antigen panel, and 60 selected specimens were tested for HCV RNA by the polymerase chain reaction (PCR). RIBA-1 and RIBA-2 gave concordant results with 86 percent of specimens, while an additional 13 percent were correctly classified by RIBA-2 but not RIBA-1. Neutralization EIA alone correctly identified 94 percent of the study group, while the remaining 6 percent required the peptide EIA or the combined neutralization-peptide assay system for correct classification. The RIBA-2 and neutralization-peptide assay systems yielded identical results for 86 percent of specimens, and these results were supported by RIA and selected PCR testing. Only 2 specimens (0.5%) were frankly discrepant, while 51 specimens were indeterminate on either (47) or both (4) assays. When either the RIBA-2 or neutralization-peptide assay yielded an indeterminate interpretation, the other system correctly classified the specimen (based on concordance with RIA and PCR data) in a high proportion (92%) of cases. The overall high degree of concordance between RIBA-2 and neutralization-peptide assays, as well as the correlating RIA and PCR results, supports the validity and utility of these supplemental anti-HCV test systems.
引用
收藏
页码:408 / 414
页数:7
相关论文
共 26 条
  • [1] DETECTION OF ANTIBODY TO HEPATITIS-C VIRUS IN PROSPECTIVELY FOLLOWED TRANSFUSION RECIPIENTS WITH ACUTE AND CHRONIC NON-A-HEPATITIS, NON-B-HEPATITIS
    ALTER, HJ
    PURCELL, RH
    SHIH, JW
    MELPOLDER, JC
    HOUGHTON, M
    CHOO, QL
    KUO, G
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1989, 321 (22) : 1494 - 1500
  • [2] INFECTIVITY OF BLOOD THAT IS IMMUNOBLOT INTERMEDIATE REACTIVE ON HEPATITIS-C VIRUS-ANTIBODY TESTING
    BELLOBUONO, A
    MOZZI, F
    PETRINI, G
    ZANELLA, A
    SIRCHIA, G
    [J]. LANCET, 1990, 336 (8710) : 309 - 309
  • [3] BUCHAKLIAN P, 1990, 2ND INT S HCV LOS AN, P46
  • [4] IMPACT OF SPECIMEN HANDLING AND STORAGE ON DETECTION OF HEPATITIS-C VIRUS-RNA
    BUSCH, MP
    WILBER, JC
    JOHNSON, P
    TOBLER, L
    EVANS, CS
    [J]. TRANSFUSION, 1992, 32 (05) : 420 - 425
  • [5] USE OF A SIGNATURE NUCLEOTIDE-SEQUENCE OF HEPATITIS-C VIRUS FOR DETECTION OF VIRAL-RNA IN HUMAN SERUM AND PLASMA
    CHA, TA
    KOLBERG, J
    IRVINE, B
    STEMPIEN, M
    BEALL, E
    YANO, M
    CHOO, QL
    HOUGHTON, M
    KUO, G
    HAN, JH
    URDEA, MS
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 1991, 29 (11) : 2528 - 2534
  • [6] CHOMCZYNSKI P, 1987, ANAL BIOCHEM, V162, P156, DOI 10.1016/0003-2697(87)90021-2
  • [7] DETECTION OF ANTIBODIES TO HEPATITIS-C VIRUS IN UNITED-STATES BLOOD-DONORS
    DAWSON, GJ
    LESNIEWSKI, RR
    STEWART, JL
    BOARDWAY, KM
    GUTIERREZ, RA
    PENDY, L
    JOHNSON, RG
    ALCALDE, X
    ROTE, KV
    DEVARE, SG
    ROBEY, WG
    PETERSON, DA
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 1991, 29 (03) : 551 - 556
  • [8] RECOMBINANT IMMUNOBLOT ASSAY FOR HEPATITIS-C VIRUS-ANTIBODY AS PREDICTOR OF INFECTIVITY
    EBELING, F
    NAUKKARINEN, R
    LEIKOLA, J
    [J]. LANCET, 1990, 335 (8695) : 982 - 983
  • [9] EVALUATION OF ANTIBODIES TO HEPATITIS-C VIRUS IN A STUDY OF TRANSFUSION-ASSOCIATED HEPATITIS
    ESTEBAN, JI
    GONZALEZ, A
    HERNANDEZ, JM
    VILADOMIU, L
    SANCHEZ, C
    LOPEZTALAVERA, JC
    LUCEA, D
    MARTINVEGA, C
    VIDAL, X
    ESTEBAN, R
    GUARDIA, J
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1990, 323 (16) : 1107 - 1112
  • [10] FANG CT, 1990, 2ND P INT S HCV LOS, P102