FAST SIMPLE AND ACCURATE MEASUREMENT OF ZEOLITE THERMAL-CONDUCTIVITY

被引:34
作者
LIU, ZY
CACCIOLA, G
RESTUCCIA, G
GIORDANO, N
机构
[1] CNR,INST TRANSFORMAT & STORAGE ENERGY,VIA S LUCIA 39,I-98126 ST LUCIA MESSINA,ITALY
[2] UNIV SCI & TECHNOL CHINA,DEPT ENGN THERMOPHYS,HEFEI,PEOPLES R CHINA
来源
ZEOLITES | 1990年 / 10卷 / 06期
关键词
hot-wire method; thermal conductivity; Zeolite;
D O I
10.1016/S0144-2449(05)80313-6
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
A simple and fast method to measure the thermal conductivity of zeolite brick is presented. The theory of the measurement and the experimental device are accurately described. Results obtained using zeolite samples produced in the CNR-TAE Institute with a specific and patented procedure confirm the accuracy of the measurement methodology, which is simple and inexpensive and can be used in any laboratory, especially for comparison measurements. © 1990 Butterworth-Heinemann.
引用
收藏
页码:565 / 570
页数:6
相关论文
共 11 条
[1]  
ANTONINI G, 1988, JUL CEC CONTR M ABS
[2]   CHEMICAL PROCESSES FOR ENERGY-STORAGE AND TRANSMISSION [J].
CACCIOLA, G ;
GIORDANO, N .
APPLIED ENERGY, 1986, 25 (04) :315-337
[3]  
CACCIOLA G, 1988, Patent No. 48591
[4]  
Carslaw H. S., 1986, CONDUCTION HEAT SOLI
[5]  
Donati A., 1987, High Temperatures - High Pressures, V19, P371
[6]   PREDICTIVE MODEL AND EXPERIMENTAL RESULTS FOR A 2-ADSORBER SOLID ADSORPTION HEAT-PUMP [J].
DOUSS, N ;
MEUNIER, FE ;
SUN, LM .
INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 1988, 27 (02) :310-316
[7]   IDENTIFICATION OF ZEOLITES FOR HEAT TRANSFORMER, CHEMICAL HEAT-PUMP AND COOLING SYSTEMS [J].
RESTUCCIA, G ;
QUAGLIATA, R .
INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 1988, 12 (01) :101-111
[8]   ZEOLITE HEAT-PUMP FOR DOMESTIC HEATING [J].
RESTUCCIA, G ;
RECUPERO, V ;
CACCIOLA, G ;
ROTHMEYER, M .
ENERGY, 1988, 13 (04) :333-342
[9]  
RESTUCCIA G, 1988, 1988 P POMP CHAL CHI, V2, P182
[10]  
TCHERNEV DI, 1988, ACHRAE T 2, V94