THE APPLICATION OF BREATH-HOLD PHASE-VELOCITY MAPPING TECHNIQUES TO THE MEASUREMENT OF CORONARY-ARTERY FLOOD FLOW VELOCITY - PHANTOM DATA AND INITIAL IN-VIVO RESULTS

被引:74
作者
KEEGAN, J
FIRMIN, D
GATEHOUSE, P
LONGMORE, D
机构
[1] Magnetic Resonance Unit, Royal Brompton National Heart and Lung Hospital, London
关键词
CORONARY ARTERY; VELOCITY MAPPING;
D O I
10.1002/mrm.1910310509
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A segmented k-space breath hold phase velocity mapping technique has been developed for the study of coronary artery blood flow velocity. In vitro validation has been performed using a number of pulsatile flow phantoms and the accuracy of the technique for determining the velocity increase at the site of a stenosis demonstrated in several phantom models. Examples of both in-plane and through-plane velocity maps of the left anterior descending and right coronary arteries of normal subjects in early diastole are presented. In one subject, through-plane velocity maps were obtained in the right and left anterior descending arteries throughout the cardiac cycle in order to generate flow velocity time curves. The problems associated with coronary artery velocity mapping are discussed.
引用
收藏
页码:526 / 536
页数:11
相关论文
共 40 条
  • [1] CORONARY ANGIOGRAPHY - MORE THAN MEETS THE EYE
    APPLEGATE, RJ
    HERRINGTON, DM
    LITTLE, WC
    [J]. CIRCULATION, 1993, 87 (04) : 1399 - 1401
  • [2] ATKINSON D, 1991, RADIOLOGY, V181, P357
  • [3] NEW METHOD TO MEASURE PHASIC CORONARY BLOOD VELOCITY IN MAN
    BENCHIMOL, A
    STEGALL, HF
    GARTLAN, JL
    [J]. AMERICAN HEART JOURNAL, 1971, 81 (01) : 93 - +
  • [4] REGRESSION OF CORONARY-ARTERY DISEASE AS A RESULT OF INTENSIVE LIPID-LOWERING THERAPY IN MEN WITH HIGH-LEVELS OF APOLIPOPROTEIN-B
    BROWN, G
    ALBERS, JJ
    FISHER, LD
    SCHAEFER, SM
    LIN, JT
    KAPLAN, C
    ZHAO, XQ
    BISSON, BD
    FITZPATRICK, VF
    DODGE, HT
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1990, 323 (19) : 1289 - 1298
  • [5] MEASUREMENT OF FLOW WITH NMR IMAGING USING A GRADIENT PULSE AND PHASE DIFFERENCE TECHNIQUE
    BRYANT, DJ
    PAYNE, JA
    FIRMIN, DN
    LONGMORE, DB
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1984, 8 (04) : 588 - 593
  • [6] NMR ANGIOGRAPHY OF CORONARY VESSELS WITH 2-D PLANAR IMAGE SCANNING
    CHO, ZH
    MUN, CW
    FRIEDENBERG, RM
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1991, 20 (01) : 134 - 143
  • [7] MAXIMAL BLOOD-FLOW VELOCITY IN SEVERE CORONARY STENOSES MEASURED WITH A DOPPLER GUIDEWIRE - LIMITATIONS FOR THE APPLICATION OF THE CONTINUITY EQUATION IN THE ASSESSMENT OF STENOSIS SEVERITY
    DIMARIO, C
    MENEVEAU, N
    GIL, R
    DEJAEGERE, P
    DEFEYTER, PJ
    SLAGER, CJ
    ROELANDT, JRTC
    SERRUYS, PW
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1993, 71 (14) : D54 - D61
  • [8] LUMEN DIAMETER OF NORMAL HUMAN CORONARY-ARTERIES - INFLUENCE OF AGE, SEX, ANATOMIC VARIATION, AND LEFT-VENTRICULAR HYPERTROPHY OR DILATION
    DODGE, JT
    BROWN, BG
    BOLSON, EL
    DODGE, HT
    [J]. CIRCULATION, 1992, 86 (01) : 232 - 246
  • [9] VALIDATION OF A DOPPLER GUIDE WIRE FOR INTRAVASCULAR MEASUREMENT OF CORONARY-ARTERY FLOW VELOCITY
    DOUCETTE, JW
    CORL, PD
    PAYNE, HM
    FLYNN, AE
    GOTO, M
    NASSI, M
    SEGAL, J
    [J]. CIRCULATION, 1992, 85 (05) : 1899 - 1911
  • [10] DOYLE M, 1993, J MAGN RESON IMAGING, V11, P3