CATHETER SIZES FOR QUANTITATIVE CORONARY ARTERIOGRAPHY

被引:25
作者
REIBER, JHC
JUKEMA, W
VANBOVEN, A
VANHOUDT, RM
LIE, KI
BRUSCHKE, AVG
机构
[1] UNIV LEIDEN HOSP,DEPT CARDIOL,2300 RC LEIDEN,NETHERLANDS
[2] UNIV GRONINGEN HOSP,DEPT CARDIOL,GRONINGEN,NETHERLANDS
[3] INTERUNIV CARDIOL INST NETHERLANDS,UTRECHT,NETHERLANDS
来源
CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS | 1994年 / 33卷 / 02期
关键词
QUANTITATIVE CORONARY ARTERIOGRAPHY; CORONARY CATHETERS; REGRESSION PROGRESSION TRIALS;
D O I
10.1002/ccd.1810330214
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
In quantitative coronary arteriography (QCA), the outer diameter of the contrast catheter is used almost exclusively as the calibration device, Since the true outer diameter of these catheters are smaller than the French sizes listed by the manufacturer, it has been advocated to measure the actual sizes with a precision micrometer. However, this represents a significant effort in the organizations of the QCA Angiographic Core Laboratories and of the participating cardiac catheterization laboratories. In the Dutch REGRESS trial on regression/progression of coronary artery disease, we have measured a total of 2,104 catheters from four different manufacturers. In 2,048 of the 2,104 catheters the variabilities in the measurements were 0.02-0.03 mm, which represents an error of only 1% of the average catheter sizes, In the remaining 56 catheter measurements, the variability was 0.04 mm, From these data we may conclude that from now on the stated mean values can be used for calibration purposes. This has important practical consequences for running clinical trials and QCA Core Laboratory operations. (C) 1994 Wiley-Liss, Inc.
引用
收藏
页码:153 / 155
页数:3
相关论文
共 7 条
[1]  
DEFEYTER P, 1993, ADV QUANTITATIVE COR, P255
[2]   PITFALLS IN THE DETERMINATION OF ABSOLUTE DIMENSIONS USING ANGIOGRAPHIC CATHETERS AS CALIBRATION DEVICES IN QUANTITATIVE ANGIOGRAPHY [J].
FORTIN, DF ;
SPERO, LA ;
CUSMA, JT ;
SANTORO, L ;
BURGESS, R ;
BASHORE, TM .
AMERICAN JOURNAL OF CARDIOLOGY, 1991, 68 (11) :1176-1182
[3]  
Koning G, 1992, Int J Card Imaging, V8, P153, DOI 10.1007/BF01137536
[4]  
Reiber J. H. C., 1991, CARDIAC IMAGING COMP, P211
[5]   ASSESSMENT OF DIMENSIONS AND IMAGE QUALITY OF CORONARY CONTRAST CATHETERS FROM CINEANGIOGRAMS [J].
REIBER, JHC ;
KOOIJMAN, CJ ;
DENBOER, A ;
SERRUYS, PW .
CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1985, 11 (05) :521-531
[6]  
Reiber JHC., 1988, NEW DEV QUANTITATIVE, P34
[7]  
REIBER JHC, 1989, AM J CARDIAC IMAGING, V3, P172