CALIBRATION OF THE ION MICROPROBE FOR THE QUANTITATIVE-DETERMINATION OF STRONTIUM, IRON, MANGANESE, AND MAGNESIUM IN CARBONATE MINERALS

被引:19
作者
SWART, PK
机构
[1] Rosenstiel School of Marine and Atmospheric Science, Marine Geology and Geophysics, University of Miami, Miami
关键词
D O I
10.1021/ac00206a015
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The necessary operating conditions have been determined for the measurement of trace concentrations of Mg, Mn, Fe, and Sr In calcite and dolomite using a Cameca 3f Ion microprobe with the energy filtering method. With this technique, the presence of Interferences can be ascertained by examining the deviation of the measured Isotopic ratios of an element from their natural values as a function of the kinetic energy acquired during the sputtering process. With the energy filtering method It Is possible, using an energy offset of −50 V, to reduce Interferences from other species at masses 24, 54, and 88 for Mg, Fe, and Sr. Although Mn has only one stable Isotope, It Is believed that a similar voltage offset may be suitable for this element. By use of these conditions, calibration lines have been established for Mg, Fe, Mn, and Sr employing 11 calclte and dolomite standards. It Is estimated that for carbonate materials, concentrations of Mn, Mg, and Sr can be quantitatively measured as low as 1 ppm and Fe as low as 10 ppm. No significant differences in calibration were observed between calcite and dolomite. The slopes and intercepts of the relationships were found to remain constant within error over periods of 3 years. © 1990, American Chemical Society. All rights reserved.
引用
收藏
页码:722 / 728
页数:7
相关论文
共 13 条
[1]  
Ahrens, 1975, PHYS CHEM EARTH, V9, P655
[2]   THERMODYNAMIC APPROACH TO QUANTITATIVE INTERPRETATION OF SPUTTERED ION MASS-SPECTRA [J].
ANDERSEN, CA ;
HINTHORNE, JR .
ANALYTICAL CHEMISTRY, 1973, 45 (08) :1421-1438
[3]  
ANDERSEN CA, 1975, NBS SPEC PUBL, V427, P79
[4]  
Herzog R. F. K., 1973, Radiation Effects, V18, P199, DOI 10.1080/00337577308232122
[5]   HIGH-RESOLUTION ION-MICROPROBE MEASUREMENT OF LEAD ISOTOPES - VARIATIONS WITHIN SINGLE ZIRCONS FROM LAC SEUL, NORTHWESTERN ONTARIO [J].
HINTON, RW ;
LONG, JVP .
EARTH AND PLANETARY SCIENCE LETTERS, 1979, 45 (02) :309-325
[6]   CARBONATE REFERENCE SAMPLES FOR ELECTRON-MICROPROBE AND SCANNING ELECTRON-MICROSCOPE ANALYSES [J].
JAROSEWICH, E ;
MACINTYRE, IG .
JOURNAL OF SEDIMENTARY PETROLOGY, 1983, 53 (02) :677-678
[7]   ION MICROPROBE ANALYSIS OF TRACE-ELEMENTS IN CALCITE WITH AN APPLICATION TO THE CATHODOLUMINESCENCE ZONATION OF LIMESTONE CEMENTS FROM THE LOWER CARBONIFEROUS OF SOUTH-WALES, UK [J].
MASON, RA .
CHEMICAL GEOLOGY, 1987, 64 (3-4) :209-224
[8]   APPLICATIONS OF THE ION MICRO-PROBE TO GEOCHEMISTRY AND COSMOCHEMISTRY [J].
SHIMIZU, N ;
HART, SR .
ANNUAL REVIEW OF EARTH AND PLANETARY SCIENCES, 1982, 10 :483-526
[10]  
SHIMIZU N, 1978, GEOCHIM COSMOCHIM AC, V42, P1312