ION-SELECTIVE MEMBRANES WITH LOW PLASTICIZER CONTENT - ELECTROANALYTICAL CHARACTERIZATION AND BIOCOMPATIBILITY STUDIES

被引:102
作者
LINDNER, E
COSOFRET, VV
UFER, S
BUCK, RP
KAO, WJ
NEUMAN, MR
ANDERSON, JM
机构
[1] UNIV N CAROLINA,DEPT CHEM,CHAPEL HILL,NC 27599
[2] CASE WESTERN RESERVE UNIV,INST PATHOL,DEPT BIOMED ENGN,CLEVELAND,OH 44106
来源
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH | 1994年 / 28卷 / 05期
关键词
D O I
10.1002/jbm.820280509
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
High molecular weight poly(vinyl chloride) and aliphatic polyurethane (Tecoflex)-based ion selective membranes, with normal and reduced amounts of plasticizer, as well as without plasticizer, were tested with respect to their analytical properties, their biocompatibility, and cellular responses. The analytical properties of the membranes did not change significantly within a wide range of polymer to plasticizer ratios. However, the membranes with reduced plasticizer content had better adhesive properties, less anion interference, extended life time, and better biocompatibility. Using the cage implant system, the results showed that an increase of plasticizer weight percent in Tecoflex membranes correlated positively with the increase in host inflammatory response up to 14 days of implantation. The results also demonstrated that both PVC and Tecoflex-based ion-selective membranes with the most common membrane composition (1:2 polymer to plasticizer ratio) exhibited a similar acute inflammatory response, but the PVC-based membrane elicited a reduced chronic inflammatory response when compared with the Tecoflex-based membrane. (C) 1994 John Wiley and Sons, Inc.
引用
收藏
页码:591 / 601
页数:11
相关论文
共 43 条
  • [1] LIPOPHILIC SALTS AS MEMBRANE ADDITIVES AND THEIR INFLUENCE ON THE PROPERTIES OF MACROELECTRODES AND MICROELECTRODES BASED ON NEUTRAL CARRIERS
    AMMANN, D
    PRETSCH, E
    SIMON, W
    LINDNER, E
    BEZEGH, A
    PUNGOR, E
    [J]. ANALYTICA CHIMICA ACTA, 1985, 171 (MAY) : 119 - 129
  • [2] AMMANN D, 1986, ION SELECTIVE MICROE
  • [3] AMMANN D, 1981, ION SELECTIVE ELECTR, V3, P179
  • [4] ANION RESPONSES AND POTENTIAL FUNCTIONS FOR NEUTRAL CARRIER MEMBRANE ELECTRODES
    BOLES, JH
    BUCK, RP
    [J]. ANALYTICAL CHEMISTRY, 1973, 45 (12) : 2057 - 2062
  • [5] Buck R. P., 1976, PURE APPL CHEM, V48, P127
  • [6] ANION EFFECTS ON DONNAN FAILURE OF AMINATED-POLY(VINYL CHLORIDE)-BASED AND NEUTRAL-CARRIER-BASED PH SENSORS
    BUCK, RP
    COSOFRET, VV
    LINDNER, E
    [J]. ANALYTICA CHIMICA ACTA, 1993, 282 (02) : 273 - 281
  • [7] ELECTROCHEMICAL PERFORMANCE, BIOCOMPATIBILITY, AND ADHESION OF NEW POLYMER MATRICES FOR SOLID-STATE ION SENSORS
    CHA, GS
    LIU, D
    MEYERHOFF, ME
    CANTOR, HC
    MIDGLEY, AR
    GOLDBERG, HD
    BROWN, RB
    [J]. ANALYTICAL CHEMISTRY, 1991, 63 (17) : 1666 - 1672
  • [8] EVIDENCE FOR A WATER-RICH SURFACE REGION IN POLY(VINYL CHLORIDE)-BASED ION-SELECTIVE ELECTRODE MEMBRANES
    CHAN, ADC
    LI, XZ
    HARRISON, DJ
    [J]. ANALYTICAL CHEMISTRY, 1992, 64 (21) : 2512 - 2517
  • [9] NEW NEUTRAL CARRIER-BASED H+ SELECTIVE-MEMBRANE ELECTRODES
    COSOFRET, VV
    NAHIR, TM
    LINDNER, E
    BUCK, RP
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1992, 327 (1-2): : 137 - 146
  • [10] Coury A J, 1988, J Biomater Appl, V3, P130, DOI 10.1177/088532828800300202