DETERMINATION OF ASCORBIC-ACID AND DEHYDROASCORBIC ACID IN JUICES BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH ELECTROCHEMICAL DETECTION USING L-CYSTEINE AS PRECOLUMN REDUCTANT

被引:35
作者
IWASE, H
ONO, I
机构
[1] Ajinomoto Co., Inc., Central Research Laboratories, Kawasaki-ku, Kawasaki, 210
关键词
D O I
10.1016/0021-9673(93)83364-X
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Determination of ascorbic acid (AA) and dehydroascorbic acid (DHAA) in juices was performed by high-performance liquid chromatography with electrochemical detection using L-cysteine as precolumn reductant. This method was suitable for the determination of AA and total AA (AA + DHAA) in juices. The mild reduction of DHAA to AA with L-cysteine took ca. 15 min, and the retention time of AA was ca. 15 min. The detection limit (signal-to-noise ratio = 2) was ca. 0.15 ng. The method was selective and reproducible (relative standard deviation 2.6-3.2% for AA and 2.1-3.2% for total AA). The calibration graph for AA was linear in the range 0.1-10 ng. The recovery of AA was over 90% by the standard addition method.
引用
收藏
页码:215 / 220
页数:6
相关论文
共 15 条
[1]   A HIGHLY SENSITIVE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY METHOD FOR THE ESTIMATION OF ASCORBIC AND DEHYDROASCORBIC ACID IN TISSUES, BIOLOGICAL-FLUIDS, AND FOODS [J].
BEHRENS, WA ;
MADERE, R .
ANALYTICAL BIOCHEMISTRY, 1987, 165 (01) :102-107
[2]  
BEHRENS WA, 1992, J LIQ CHROMATOGR, V15, P75
[3]  
DELEENHEER AP, 1992, MODERN CHROMATOGRAPH, P235
[4]   RAPID HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF ASCORBIC-ACID AND COMBINED ASCORBIC-ACID DEHYDROASCORBIC ACID IN BEVERAGES [J].
DENNISON, DB ;
BRAWLEY, TG ;
HUNTER, GLK .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 1981, 29 (05) :927-929
[5]   DETERMINATION OF ASCORBIC AND DEHYDROASCORBIC ACID IN POTATOES (SOLANUM-TUBEROSUM) AND STRAWBERRIES USING ION-EXCLUSION CHROMATOGRAPHY [J].
GRAHAM, WD ;
ANNETTE, D .
JOURNAL OF CHROMATOGRAPHY, 1992, 594 (1-2) :187-194
[6]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF ASCORBIC-ACID IN HUMAN TEARS [J].
HOWARD, RR ;
PETERSON, T ;
KASTL, PR .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1987, 414 (02) :434-439
[7]   SIMULTANEOUS DETERMINATION OF URIC AND ASCORBIC ACIDS IN HUMAN-SERUM BY REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH ELECTROCHEMICAL DETECTION [J].
IRIYAMA, K ;
YOSHIURA, M ;
IWAMOTO, T ;
OZAKI, Y .
ANALYTICAL BIOCHEMISTRY, 1984, 141 (01) :238-243
[8]  
IWASE H, 1992, J CHROMATOGR, V505, P277
[9]  
KISSINGER PT, 1977, ANAL CHEM, V49, pA477
[10]  
KOTNINK MA, 1985, J LIQ CHROMATOGR, V8, P31