RADIOGRAPHIC EVALUATION OF POROSITIES IN REMOVABLE PARTIAL DENTURE CASTINGS
被引:17
作者
:
LEWIS, AJ
论文数:
0
引用数:
0
h-index:
0
机构:
University of Western Australia, Dental School, Perth, WA
LEWIS, AJ
机构
:
[1]
University of Western Australia, Dental School, Perth, WA
来源
:
JOURNAL OF PROSTHETIC DENTISTRY
|
1978年
/ 39卷
/ 03期
关键词
:
D O I
:
10.1016/S0022-3913(78)80095-X
中图分类号
:
R78 [口腔科学];
学科分类号
:
1003
[口腔医学]
;
摘要
:
Most of the removable partial denture castings examined showed radiographic evidence of internal porosity. In general the porosity occurred in characteristic regions associated with abrupt changes in cross-sectional thickness. These were located either within the partial denture framework or at the casting-sprue junctions. The porosity is due to metal shrinkage caused by a premature solidification at some point, which in turn interferes with a controlled unidirectional solidification of the casting. © 1978 C. V. Mosby Company.