COMPARISON OF DIGITAL AND CONVENTIONAL MUSCULOSKELETAL RADIOGRAPHY - AN OBSERVER PERFORMANCE STUDY

被引:64
作者
WEGRYN, SA
PIRAINO, DW
RICHMOND, BJ
SCHLUCHTER, MD
UETANI, M
FREED, HA
MEZIANE, MA
BELHOBEK, GA
机构
[1] CLEVELAND CLIN FDN,DEPT RADIOL,1 CLIN CTR,9500 EUCLID AVE,CLEVELAND,OH 44195
[2] CLEVELAND CLIN FDN,DEPT BIOSTAT & EPIDEMIOL,CLEVELAND,OH 44195
[3] NAGASAKI UNIV,DEPT RADIOL,NAGASAKI 852,JAPAN
关键词
Bones; radiography; 40.11; 40.1215; Radiography; comparative studies; digital; Receiver operating characteristic curve (ROC); Video systems;
D O I
10.1148/radiology.175.1.2315485
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Interpretations of 122 musculoskeletal radiographs were compared with interpretations of their digital counterparts at a resolution of 1,024 × 840 × 12 bits. Images were evaluated by four readers and included subtle and nonsubtle abnormalities and normal findings. Joint receiver operating characteristic (ROC) analysis results were averaged over all readers and demonstrated no statistically significant difference between the two imaging methods. High interobserver variability limited identifiable differences. Review of cases with subtle findings on the digital system at a resolution of 2,048 × 1,680 × 12 bits (2.5 line pairs per millimeter) revealed adequate visualization of the abnormality in every case. It is concluded that a resolution of 1,024 × 840 × 12 bits is adequate for the interpretation of many musculoskeletal abnormalities but that a resolution of 2,048 × 1,680 × 12 bits is needed for visualization of some subtle abnormalities.
引用
收藏
页码:225 / 228
页数:4
相关论文
共 13 条
[1]   DIGITAL AND CONVENTIONAL CHEST IMAGING - A MODIFIED ROC STUDY OF OBSERVER PERFORMANCE USING SIMULATED NODULES [J].
CHAKRABORTY, DP ;
BREATNACH, ES ;
YESTER, MV ;
SOTO, B ;
BARNES, GT ;
FRASER, RG .
RADIOLOGY, 1986, 158 (01) :35-39
[2]   DIGITAL MAMMOGRAPHY - ROC STUDIES OF THE EFFECTS OF PIXEL SIZE AND UNSHARP-MASK FILTERING ON THE DETECTION OF SUBTLE MICROCALCIFICATIONS [J].
CHAN, HP ;
VYBORNY, CJ ;
MACMAHON, H ;
METZ, CE ;
DOI, K ;
SICKLES, EA .
INVESTIGATIVE RADIOLOGY, 1987, 22 (07) :581-589
[3]   MAXIMUM-LIKELIHOOD ESTIMATION OF PARAMETERS OF SIGNAL-DETECTION THEORY AND DETERMINATION OF CONFIDENCE INTERVALS - RATING-METHOD DATA [J].
DORFMAN, DD ;
ALF, E .
JOURNAL OF MATHEMATICAL PSYCHOLOGY, 1969, 6 (03) :487-&
[4]   THE EFFECT OF VARYING SPATIAL-RESOLUTION ON THE DETECTABILITY OF DIFFUSE PULMONARY NODULES - ASSESSMENT WITH DIGITIZED CONVENTIONAL RADIOGRAPHS [J].
FOLEY, WD ;
WILSON, CR ;
KEYES, GS ;
DIBIANCA, FA ;
SCANLON, GT ;
SCHLEUTER, D ;
LAWSON, TL .
RADIOLOGY, 1981, 141 (01) :25-31
[5]  
GITLIN JN, 1986, RADIOL CLIN N AM, V24, P55
[6]   DIGITAL AND CONVENTIONAL CHEST IMAGES - OBSERVER PERFORMANCE WITH FILM DIGITAL RADIOGRAPHY SYSTEM [J].
GOODMAN, LR ;
FOLEY, WD ;
WILSON, CR ;
RIMM, AA ;
LAWSON, TL .
RADIOLOGY, 1986, 158 (01) :27-33
[7]   CLINICAL-TRIAL OF DIGITAL TELERADIOLOGY IN THE PRACTICE OF EMERGENCY RADIOLOGY [J].
KAGETSU, NJ ;
ZULAUF, DRP ;
ABLOW, RC .
RADIOLOGY, 1987, 165 (02) :551-554
[8]   DIGITAL GASTROINTESTINAL IMAGING - THE EFFECT OF PIXEL SIZE ON DETECTION OF SUBTLE MUCOSAL ABNORMALITIES [J].
KASTAN, DJ ;
ACKERMAN, LV ;
FECZKO, PJ .
RADIOLOGY, 1987, 162 (03) :853-856
[9]   SPATIAL-RESOLUTION REQUIREMENTS FOR DIGITAL CHEST RADIOGRAPHS - AN ROC STUDY OF OBSERVER PERFORMANCE IN SELECTED CASES [J].
LAMS, PM ;
COCKLIN, ML .
RADIOLOGY, 1986, 158 (01) :11-19
[10]   DIGITAL RADIOGRAPHY OF SUBTLE PULMONARY ABNORMALITIES - AN ROC STUDY OF THE EFFECT OF PIXEL SIZE ON OBSERVER PERFORMANCE [J].
MACMAHON, H ;
VYBORNY, CJ ;
METZ, CE ;
DOI, K ;
SABETI, V ;
SOLOMON, SL .
RADIOLOGY, 1986, 158 (01) :21-26