AUDIT IN ACTION - SIGNIFICANT REDUCTION OF DOUBLE-CONTRAST BARIUM ENEMA SCREENING TIME WITH NO LOSS OF EXAMINATION QUALITY

被引:12
作者
HORTON, D
COOK, AM
TAYLOR, AD
机构
[1] Department of Radiology, Hull Royal Infirmary, Kingston upon Hull HU3 2JZ, Anlaby Road
关键词
BARIUM ENEMA; SCREENING TIME;
D O I
10.1259/0007-1285-65-774-507
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The double-contrast barium enema is an examination of high radiation exposure to the patient. As part of a departmental audit, our own fluoroscopic screening times were being recorded. A study was undertaken to see if a determined effort could reduce the screening time without having a detrimental effect on the quality of the examinations. Methods of screening time reduction were identified and then implemented by two radiologists. In the period before the study the average screening time for radiologists A and B was 2.6 min and 3.2 min, respectively (over 56 examinations). After implementation of the changes, the average screening time for both was 0.9 min (over 50 examinations). This is a statistically significant reduction (p < 0.01). The examinations were assessed independently by a gastroradiologist. No difference in the quality of the examinations was identified. We conclude that a significant reduction of screening time for the double-contrast barium enema can be achieved without loss of examination quality.
引用
收藏
页码:507 / 509
页数:3
相关论文
共 9 条
[1]   OVEREXPOSURE TO RADIOLOGY [J].
DELACEY, G .
BRITISH MEDICAL JOURNAL, 1987, 295 (6607) :1162-1163
[2]   A SURVEY OF RADIATION-DOSES TO PATIENTS IN 5 COMMON DIAGNOSTIC EXAMINATIONS .1. PRINCIPLES AND TECHNIQUES OF DOSE EVALUATION BY INDIRECT MEASUREMENTS .2. SURVEY RESULTS [J].
HARRISON, RM ;
CLAYTON, CB ;
DAY, MJ ;
OWEN, JP ;
YORK, MF .
BRITISH JOURNAL OF RADIOLOGY, 1983, 56 (666) :383-395
[3]  
HARRISON RM, 1991, ADV HOSP TECHNOL, V2, P37
[4]   PATIENT DOSE REDUCTION IN DIAGNOSTIC-RADIOLOGY [J].
KERR, IH .
CLINICAL RADIOLOGY, 1991, 43 (01) :2-3
[5]  
NOLAN DJ, 1991, BRIT J HOSP MED, V45, P337
[6]   DOSES TO PATIENTS FROM ROUTINE DIAGNOSTIC-X-RAY EXAMINATIONS IN ENGLAND [J].
SHRIMPTON, PC ;
WALL, BF ;
JONES, DG ;
FISHER, ES ;
HILLIER, MC ;
KENDALL, GM ;
HARRISON, IRM .
BRITISH JOURNAL OF RADIOLOGY, 1986, 59 (704) :749-758
[7]  
1990, WHICH JAN
[8]  
1990, DOCUMENTS NRPB, V3
[9]  
1990, DOCUMENTS NRPB, V1