EXPERIMENTAL RESULTS FOR CAPILLARY LOOPED PIPE APPLIED TO DIRECT COOLING METHOD

被引:5
作者
MIYASAKA, A [1 ]
NAKAJIMA, K [1 ]
TSUNODA, H [1 ]
机构
[1] NIPPON TELEGRAPH & TEL PUBL CORP, RADIO COMMUN SYST LABS, KANAGAWA 23803, JAPAN
关键词
D O I
10.2514/3.633
中图分类号
O414.1 [热力学];
学科分类号
摘要
The heat transport characteristics of capillary looped pipes are obtained from experimental results. Both indirect-cooling and direct-cooling capillary looped pipes were tested, An indirect-cooling looped pipe was tested to determine the now direction of the working fluid and the relationship between the liquid charge quantity and the heat transfer characteristics. Tests show that using the direct-cooling configuration is superior to the indirect-cooling configuration.
引用
收藏
页码:96 / 100
页数:5
相关论文
共 2 条
[1]
GOTTSCHLICH JM, 1989, SAE TECHNICAL PAPER
[2]
NELSON LA, 1978, AIAA HEAT PIPE C NEW, P373