HEMOLYTIC DIFFERENCES AMONG ARTIFICIAL CARDIAC VALVES USED IN A VENTRICULAR ASSIST PUMP

被引:7
作者
BILLY, GG [1 ]
MILLER, CA [1 ]
PALLONE, MN [1 ]
DONACHY, JH [1 ]
PIERCE, WS [1 ]
机构
[1] PENN STATE UNIV,MILTON S HERSHEY MED CTR,DEPT SURG,DIV CARDIOTHORAC SURG,ARTIFICIAL ORGANS SECT,HERSHEY,PA 17033
关键词
HEMOLYSIS; VENTRICULAR ASSIST DEVICES; CARDIAC VALVES; BACK-FLOW AND HEMODYNAMICS;
D O I
10.1111/j.1525-1594.1995.tb02338.x
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Ventricular assist devices (VADs) required for cardiac support may produce clinically significant hemolysis. VAD valves differ in both mechanics and hemodynamics. Therefore, we examined a ball valve, a modified tilting disc (MTD) valve, a polyurethane trileaflet valve, and a Bjork-Shiley monostrut valve to determine their degrees of hemolysis. The valves were tested in a Pierce-Donachy VAD which pumped fresh bovine blood through a mock loop. Blood samples were analyzed for hematocrit and plasma hemoglobin, from which the indices of hemolysis were calculated. A one-way analysis of variance indicated significant differences between certain valves. The MTD was the most hemolytic. No significant hemolytic difference was found between the trileaflet and monostrut valves despite their different designs. The monostrut valve and the MTD valve were hemolytically very different despite their similar design. This study suggests that the valve type significantly affects the hemolysis produced by the VAD.
引用
收藏
页码:339 / 343
页数:5
相关论文
共 23 条
[1]  
Baldwin J T, 1990, ASAIO Trans, V36, pM274
[2]  
Baldwin J T, 1991, ASAIO Trans, V37, pM348
[3]   RAPID METHOD FOR ESTIMATION OF PLASMA HAEMOGLOBIN LEVELS [J].
CRIPPS, CM .
JOURNAL OF CLINICAL PATHOLOGY, 1968, 21 (01) :110-&
[4]   INTRA-VASCULAR HEMOLYSIS IN LATE COURSE OF AORTIC-VALVE REPLACEMENT - RELATION TO VALVE TYPE, SIZE, AND FUNCTION [J].
DALE, J ;
MYHRE, E .
AMERICAN HEART JOURNAL, 1978, 96 (01) :24-30
[5]  
FALK RH, 1979, THORAX, V34, P746, DOI 10.1136/thx.34.6.746
[6]   THROMBOEMBOLIC AND HEMORRHAGIC RISK IN MECHANICAL AND BIOLOGICAL AORTIC PROSTHESES [J].
FARAH, E ;
ENRIQUEZSARANO, M ;
VAHANIAN, A ;
HOULEGATTE, JP ;
BOUBAKER, A ;
ROGER, V ;
ACAR, J .
EUROPEAN HEART JOURNAL, 1984, 5 :43-47
[7]   ESTIMATION OF SHEAR STRESS-RELATED BLOOD DAMAGE IN HEART-VALVE PROSTHESES - INVITRO COMPARISON OF 25 AORTIC VALVES [J].
GIERSIEPEN, M ;
WURZINGER, LJ ;
OPITZ, R ;
REUL, H .
INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1990, 13 (05) :300-306
[8]   TURBULENT STRESS MEASUREMENTS DOWNSTREAM OF 6 MECHANICAL AORTIC VALVES IN A PULSATILE FLOW MODEL [J].
HASENKAM, JM ;
NYGAARD, H ;
GIERSIEPEN, M ;
REUL, H ;
STODKILDEJORGENSEN, H .
JOURNAL OF BIOMECHANICS, 1988, 21 (08) :631-645
[9]  
JARVIS P, 1991, T AM SOC ART INT ORG, V37, P27
[10]  
KORMOS RL, 1987, T AM SOC ART INT ORG, V33, P413